Section: extension to boundary model and some bibs
This commit is contained in:
@@ -70,6 +70,8 @@ Address: Universität Heidelberg, Institut für Theoretische Astrophysik, Albert
|
||||
\phantom{MM} \textit{Jonas Kellerer\\ Address: Karlsruher Institut für Technologie,
|
||||
Institut für Experimentelle Teilchenphysik, Campus Nord, Postfach 36 40, 76021 Karlsruhe\\jonas.kellerer@kit.edu}
|
||||
|
||||
%% die ü funktionieren hier nicht
|
||||
|
||||
\vfill
|
||||
%\begin{center}
|
||||
%\textbf{The length of the project description is restricted to 18 pages (font 12 pt)!}
|
||||
@@ -90,7 +92,10 @@ Institut für Experimentelle Teilchenphysik, Campus Nord, Postfach 36 40, 76021
|
||||
\textit{(about 0.5 to 1 page)}
|
||||
|
||||
%%TODO Referenz KATRIN Experiment, KATRIN First Light
|
||||
The KATRIN experiment aims at determining the neutrino mass to an accuracy better than 1 eV. In the experiment neutrinos are generated through the decay of tritium into ${}^3\mathrm{He}$. The neutrino mass can be deduced by measuring the spectrum of electrons from the tritium decay. A finite mass of the neutrino will result in a deviation at the end point of the electron spectrum. The heart of the KATRIN experiment is a large volume filled with Tritium gas - the Windowless Gaseous Tritium Source (WGTS) - that will produce a large amount of electrons from the decay process of Tritium into Helium. With a very sensitive spectrometer the electron spectrum can be measured in very great detail, which allows for a much stricter limit on the neutrino mass.
|
||||
%% Standart katrin anfang:
|
||||
%% The Karlsruhe TRitium Neutrino (KATRIN) experiment \cite{collaboration2001katrin}\cite{Kleesiek2019} aims to determine the effective neutrino mass with a sensitivity of $m_\nu = \SI{0.2}{eV/c^2} (90\% C.L.) in a direct approach using the $\beta$-decay of molecular tritium and a MAC-E filter spectrometer. The neutrino mass is extracted from a fit of moddelled $\beta$-decay spectra to the measured electron spectrum.
|
||||
The KATRIN experiment aims at determining the neutrino mass to an accuracy better than 1 eV. In the experiment neutrinos are generated through the decay of tritium into ${}^3\mathrm{He}$. The neutrino mass can be deduced by measuring the spectrum of electrons from the tritium decay. A finite mass of the neutrino will result in a deviation at the end point of the electron spectrum.
|
||||
The heart of the KATRIN experiment is a large volume filled with Tritium gas - the Windowless Gaseous Tritium Source (WGTS) \cite{Robertson1991}- that will produce large amounts of electrons from the decay process of Tritium into Helium. With a very sensitive spectrometer the electron spectrum can be measured in very great detail, which allows for a much stricter limit on the neutrino mass.
|
||||
|
||||
In order to get precise measurements on the neutrino mass it is not only mandatory to acquire enough statistics, which is given by the large amount of Tritium gas. It is also necessary to consider all processes inside the source that may alter the electron spectrum. It has been noted already by \cite{ferenc2005} that the interaction of primary electrons from the Tritium decay and the Tritium gas produces a large number of secondary electrons. A detailed analysis showed that the density of charged particles is large enough to achieve a collective behavior - inside the WGTS a plasma is formed.
|
||||
|
||||
@@ -111,7 +116,7 @@ The electric potential generated by the plasma leads to a change in the electron
|
||||
%\textit{(about 1 to 2 pages)}
|
||||
|
||||
|
||||
The physical situation of the WGTS inside the KATRIN experiment is rather intricate: Tritium gas is injected, various pumping mechanisms lead to a strongly inhomogeneous gas density. The tritium gas then emits primary electrons that will initiate a cascade of electrons through ionization and other atomic and molecular processes. A strong magnetic field will guide the electrons through the WGTS and different materials used in the WGTS will produce a contact potential and subsequently an electric field. In various projects these effects have been researched before as will be described below. Additionally a fluid description of the plasma has been tried
|
||||
The physical situation of the WGTS inside the KATRIN experiment is rather intricate: Tritium gas is injected, various pumping mechanisms lead to a strongly inhomogeneous gas density \cite{Priester2015}. The tritium gas then emits primary electrons that will initiate a cascade of electrons through ionization and other atomic and molecular processes. A strong magnetic field \cite{Arenz_2018} will guide the electrons through the WGTS and different materials used in the WGTS will produce a contact potential and subsequently an electric field \cite{Schoenung2016_1000056077}. In various projects these effects have been researched before as will be described below. Additionally a fluid description of the plasma has been tried \cite{Kuckert2016_1000065077}.
|
||||
|
||||
|
||||
|
||||
@@ -119,7 +124,7 @@ The physical situation of the WGTS inside the KATRIN experiment is rather intric
|
||||
|
||||
\subsection{Neutral gas flow}
|
||||
|
||||
Tritium gas is injected in the center of the WGTS and flows to both sides (rear wall and detector), where the gas is pumped off. The general geometry is given in Fig. \ref{fig:wgts_aufbau}. The gas density is dropping off to the ends of the WGTS. Especially behind the pump ports the density is decreasing by orders of magnitude. The collisionality of the gas flow decreases along with the gas density, as a consequence the physical description changes over the length of the WGTS.
|
||||
Tritium gas is injected in the center of the WGTS and flows to both sides (rear wall and detector), where the gas is pumped off \cite{Grohmann2008}. The general geometry is given in Fig. \ref{fig:wgts_aufbau}. The gas density is dropping off to the ends of the WGTS. Especially behind the pump ports the density is decreasing by orders of magnitude. The collisionality of the gas flow decreases along with the gas density, as a consequence the physical description changes over the length of the WGTS.
|
||||
|
||||
\begin{figure}[!htb]
|
||||
\centering
|
||||
@@ -160,6 +165,7 @@ The detailed flow speeds are required to calculate the primary electron spectrum
|
||||
\subsection{Atomic and molecular processes}
|
||||
|
||||
%%TODO JK: Referenz auf Ferenc' Monte Carlo Paper einfügen.
|
||||
%% ich kenne nur dieses eine, die du auch drinnen hast "ferenc2005", ich habe mal der Rest dazu ergänzt.
|
||||
|
||||
The primary electrons alone are not sufficient to maintain the plasma condition within the WGTS, the emission of secondary electrons is the source of the majority of electrons. Within the source electrons and tritium interact via various processes - including but not limited to ionization, recombination and elastic scattering.
|
||||
|
||||
@@ -202,17 +208,8 @@ The resulting plasma potential is shown in Fig. \ref{fig:kuckert}. The model its
|
||||
|
||||
%%TODO JK: Hier etwas zu den Vorarbeiten schreiben
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
The ACRONYM code uses a three dimensional grid to store and calculate electromagnetic fields. The grid is alligned with the cartesian axis of the simulated volume. Thus in the past the boundary conditions (periodic, conductive walls, absorbing walls) were applied to planes parallel to the coordinate planes. In contrast the source of KATRIN has a cylindrical shape. So new boundary algorithms had to be implemented. They were adapted from \cite{Nieter2009} sceme, which was developed for metallic perfectly conductive curved boundaries. The algorithm provides solutions which retain the second order accuracy while keeping the additional computational cost at a minimum. The accuracy of the algorithm in ACRONYM can be tested via a cavity mode excitation method. This method applies a analytical calculated cavity mode for a certain time to the system. When the excitation is turned off the system continues to oscillate. By compairing the frequency of the analytical solution and of the excited mode can the algorithm be tested. Additionally to the modification of the fields the particle behavior had to be adapted. So the particles, which hit the cylinder surface are now absorbed.
|
||||
A major input for the calculation with ACRONYM is the electron energy density distribution of the electrons inside the WGTS. The distribution is determined numerically by the KARL code (see above) and can have in general arbitrary shape. Hence a new injection method was developed to include particles of arbitary energy distribution.
|
||||
|
||||
|
||||
%-------------------------------------------------------------------------------------------------%
|
||||
|
||||