@@ -64,9 +64,27 @@ This chapter comprises an incomplete list of simulations used in the plasma and
\subsection{Rear wall}
The rear wall is not electrically connected to the rest of the beam tube and maybe biased with the voltage $U_\text{rw}$. The current between the rear wall and ground can be measured.
The rear wall is not electrically connected to the rest of the beam tube and maybe biased with the voltage $U_\text{rw}$ (cf. Fig. \ref{fig:rearwall}). The current between the rear wall and ground can be measured.
From a plasma physical viewpoint the situation may be best described as similar to a Langmuir probe. The main result is depicted in Fig. \ref{fig:current50column}
\begin{figure}
\begin{center}
\pgfimage[width=0.8\textwidth]{rearwall}
\end{center}
\caption{Schematic of the rear wall}
\label{fig:rearwall}
\end{figure}
From a plasma physical viewpoint the situation may be best described as similar to a Langmuir probe. A very simplified on the typical current-voltage diagram of a Langmuir probe is given in Fig. \ref{fig:langmuir}.
\begin{figure}
\begin{center}
\pgfimage[width=0.8\textwidth]{langmuir}
\end{center}
\caption{Sketch of the U-I-diagram for a Langmuir probe. Stolen from the friendly people at Impedans Ltd.}
\label{fig:langmuir}
\end{figure}
The main result is depicted in Fig. \ref{fig:current50column}
\begin{figure}
Hier sollte ein tolles Bild sein, auf dem man sieht, wie sich der Strom mit der Rearwall Spannung verhält
@@ -110,10 +128,59 @@ So one of the following assumptions must be wrong:
The first assumption can be tested by calculating the current by using $j=e \int_0^\infty v dN/dv dv$ which is essentially the first moment of the distribution function. Here the contribution of the \emph{blue} part of the spectrum can be compared to the red part. While the non-thermal secondaries are not as numerous as the thermal electrons they still have a significantly higher velocity resulting in a massively higher current.
\textsc{Jemand muss wirklich dieses Integral ausrechnen}
In the following the integrals $n_\text{red}, n_\text{blue}, n_\text{green}$ for the densities (the naming follows the coloring of the graph) and the respective current integrals $j_\text{red}, j_\text{blue}, j_\text{green}$.
It can easily be shown that $n_\text{red}/n_\text{green} = 4.1$ which is much less than the desired value of 9000. Even if all secondaries will eventually cool down the number of electrons is still $(n_\text{red}+n_\text{blue})/n_\text{green} = 4.1$ \footnote{All values here are normalized to the ``green'' (i.e., primary tritium decay electron) densities and currents to avoid lengthy calculations.} This in turn means, that there are not enough thermal electrons present to explain the measured current.
If one calculates the currents $j_\text{red}/j_\text{green}= 3.7\times 10^{-4}$. So in fact the factor of 9000 is wrong by a factor of 3 \footnote{This is mostly due to the fact, that there many electrons in the Maxwell distribution with velocities well above the thermal mean velocity.}. But this is still well below any current needed to explain the measurements.
The ratio $j_\text{blue}/j_\text{red}$ however is approx. 200, i.e., the contribution of secondary, non-thermal particles to the total current is well above the contribution of thermalized secondaries.
Still the contribution of all secondaries reaches only 0.08 of the primary contribution, but it is clear that thermalized electrons cannot be the source of the missing current. The large uncertainties of the secondary, nonthermal spectrum leave plenty of room for improvement (e.g., the current associated with the delta spike at $v=2\cdot 10^6$ m/s is not considered).
\subsection{Dipole section}
The dipole section is fitted with a number of dipoles that can block ions from entering the spectrometer. The general idea is that all particles enter the dipole section, ions are blocked and electrons are reflected in the spectrometer. A sketch is given in Fig. \ref{fig:dipole}.
\begin{figure}
\begin{center}
\pgfimage[width=0.8\textwidth]{dipole}
\end{center}
\caption{Schematic of the dipole section.}
\label{fig:dipole}
\end{figure}
It is a general belief that all charged particles within the WGTS are strictly bound to magnetic field line which are strictly aligned parallel to the beam tube. A consequence of this concept is, that charges will hit either end of the beam tube or has to accumulate within the beam tube.
The current has been measured. The main result is depicted in Fig. \ref{fig:current50dipole}. Two points have to be noted:
\begin{enumerate}
\item There is an equilibrium current
\item The equilibrium current is opposite to and smaller than the rear wall current
\end{enumerate}
\begin{figure}
Hier sollte ein tolles Bild sein, auf dem man sieht, wie sich der Strom am Dipol mit der Rearwall Spannung verhält
\caption{Dipole currents vs. Rear wall voltage at 50\% column density}
\label{fig:current50dipole}
\end{figure}
From the first point it can be safely assumed that the beam tube is not constantly charging up. In conjunction with the second finding it becomes clear that charges may end up somewhere else than one of the both ends of the beam tube.
In first place one has to clarify that ionisation and recombination processes do not play a role in this question: Any recombination process will diminish the ion current, but also the electron current on the other side of the beam tube.
Now a loss mechanism has to be found that allows the deflection of ions to the wall of the beam tube. This requires a process that may move ions away from their magnetic field lines. Two ideas have been discussed:
\begin{itemize}
\item Ions are coupled to the gas flow in the center of the beam tube (where we find high gas densities). At that point the possibility of pumping out along with the gas should be considered. The question here is: How large is the possible deflection from ion-neutral collisions? Is the deflection larger than the bonding to the magnetic field line?
\item The other possibility is a deflection near the dipoles: The gas density is sharply decreasing, but according to the Laura-simulations an electric field exists, that may help in deflecting the ions.
\end{itemize}
To check both possibilities it is necessary to quantitatively analyse the ion motion in the crossfire of magnetic field, neutral collision and electric field.
The sheer existence of a sizable ion loss mechanism is a larger threat for the Laura-simulations: These build on ion creation rates (as basis for charge calculations). When ions go lost in a larger fraction, the calculation of the electric field may be significantly wrong.
Ionen gehen verloren
Strom hinten soll gleich Strom vorne sein