Results section overhaul
This commit is contained in:
@@ -987,12 +987,14 @@ Ions on the other hand are created with thermal energies of the neutral gas and
|
||||
|
||||
\subsection{\cchanged{Further results for the KATRIN experiment}}}
|
||||
|
||||
\cchanged{KARL has been developed with specific applications in the context of the KATRIN experiment in mind. Therefore KARL has some features that make it unique compared to previous simulation tools. The main feature it has been developed for is the ability to calculate spectra and densities at any (predefined) point within the source. Due to the extreme inhomogeneity of the tritium density this is a very important feature which may not play such a decisive role in other Monte Carlo tools like GEANT which are primarily used for rather homogenous target materials.}
|
||||
|
||||
\cchanged{In the context of the KATRIN experiment this has a number of applications: 1) The particle distributions are an input quantity for further plasma simulations that are requiring spatially resolved data. 2) The current through the rear wall is one observable for the experiment. 3) The current through the radial wall may explain missing electrons and scattering processes close to the wall.}
|
||||
\cchanged{KARL has been developed with specific applications in the context of the KATRIN experiment in mind. From the physics point of view the following questions were mainly interesting: 1) What is the particle distributions at any point within the source? This is an input quantity for further plasma simulations that are requiring spatially resolved data. 2) What is the current through the rear wall? This is one of the few plasma physics observables for the experiment. 3) What is the current through the radial wall? Observations from (2) suggest missing electrons and scattering processes close to the wall.}
|
||||
|
||||
\cchanged{The main feature developed in KARL is the ability to calculate spectra and densities at any (predefined) point within the source. Due to the extreme inhomogeneity of the tritium density this is a very important feature which may not play such a decisive role in other Monte Carlo tools like GEANT which are primarily used for rather homogenous target materials. Results for these new applications will be presented below.}
|
||||
|
||||
%The absolute current to the tube is also influenced by the density profile of electrons and ions. There is no analytic expression of the radial currents. It can be seen that the shape of the current towards the beam tube is similar to the shape of the neutral particle density. This is caused by the increased elastic scattering probability in the center due to the increased neutral gas density. The T$^+$ current is below the T$_3^+$ current, which is caused by the density difference and the different Larmor radius of the two ion species. The current of T$^+$ is in the same order of magnitude than the current of the electrons, even though the masses of both species are significantly different. This behavior is caused by the large difference in density. There is a contribution of T$_2^{+}$ to the radial current. This means that there must be a non-negligible amount of charge transfer reactions, or that enough T$_2^{+}$ is created close to the beam tube walls. The shape of the T$_2^+$ current does not coincide perfectly with the tritium density. Thus, it must be assumed in first order that both effects play a role.
|
||||
|
||||
\subsubsection{\cchanged{Position dependent spectra}}
|
||||
|
||||
\changed{The composition of different species with respect to the position along the $z$-axis is one example of the outputs of the KARL code. Fig. \ref{fig:densities_all_vs_z} shows the graph where one can see that the electron density resembles the tritium gas density, while T$_2^+$ has a flat distribution. T$_3^+$ as a product of clustering has its density maximum also farther out. In general the higher clusters have a much higher density than the one- and two-atomic ions.}
|
||||
|
||||
\begin{figure}[tbp]
|
||||
@@ -1002,6 +1004,10 @@ Ions on the other hand are created with thermal energies of the neutral gas and
|
||||
\label{fig:densities_all_vs_z}
|
||||
\end{figure}
|
||||
|
||||
\subsubsection{\cchanged{Position dependent currents}}
|
||||
|
||||
\cchanged{Charged particle currents within the KATRIN tritium source are relevant as a diagnostic parameter since the current at the end of the WGTS can be measured. Additionally ion currents are an input quantity for subsequent plasma simulations. }
|
||||
|
||||
\changed{
|
||||
The longitudinal particle current was determined through 33 virtual planes in longitudinal direction. The planes were aligned in such a way that the first and last longitudinal plane coincide with the rear wall and}\cchanged{ the end of the source.}\changed{. The corresponding longitudinal current profile can be found in Fig. \ref{fig:Iz_vs_z}.
|
||||
}
|
||||
|
||||
Reference in New Issue