KARL paper fixed plot "Radial current vs magnetic field"
This commit is contained in:
@@ -716,7 +716,7 @@ The list used in the simulation to keep track of the simulated particles. Partic
|
||||
\section{Test cases}
|
||||
\label{sec:test}
|
||||
|
||||
The code was tested thoroughly, including a comparison of specific simulations with expectations. These expectations were formulated for scenarios where an analytical expression of the simulation output can be derived. For these simulations, each interaction was investigated detached from the others. \changed{More complex test cases, with the influence of multiple interactions at the same time where not performed due to the lack of analytical expectations or experimental data. \\
|
||||
The code was tested thoroughly, including a comparison of specific simulations with expectations. These expectations were formulated for scenarios where an analytical expression of the simulation output can be derived. For these simulations, each interaction was investigated detached from the others. \changed{More complex test cases, with the influence of multiple interactions at the same time were not performed due to the lack of analytical expectations or experimental data. \\
|
||||
Within the `test\_cases' directory in the code repository a subdirectory for each test case is provided. These subdirectories contain the parameter and plotting files used to obtain the corresponding data presented in this section. The used output files will be provided via an external website.}
|
||||
%The inclined reader is referred to \citep{Kellerer_2022} for a description of all the tests. Here, only a special test case shall be mentioned, because of its importance: the test of elastic scattering. One can show with this test that the method of density fields, the treatment of interactions in general and movement of particles are implemented correctly because they all are a prerequisite for the correct result.
|
||||
|
||||
@@ -972,7 +972,7 @@ Ions on the other hand are created with thermal energies of the neutral gas and
|
||||
|
||||
\subsection{Comparison to other Monte Carlo tools}
|
||||
|
||||
To our knowledge KARL is the only freely available Monte Carlo simulation for tritium based experiments. There are however other attempts to model the processes inside the KATRIN experiment. The earliest example is the paper by Nastoyashchii et al. \citep{Nastoyashchii:2005aa}. They follow the idea of a Monte Carlo code where events are generated from the decay of the tritium gas within the source. Most of the elastic and inelastic scattering processes which are implemented in the KARL code are also present in the code by Nastoyashchii et al. with recombination being the remarkable exemption. The most striking difference however is the lack of spatial resolution: The only result of the code is the lifetime of particles in the source (and the spectrum derived from that). Due to the extreme inhomogeneity of the tritium density the results produced by this approach are in many cases not applicable. The results of KARL are compared to this approach in Fig. \ref{fig:Nastoyashchii_comp}.
|
||||
\changed{To our knowledge KARL is the only freely available Monte Carlo simulation for tritium based experiments. There are however other attempts to model the processes inside the KATRIN experiment. The earliest example is the paper by Nastoyashchii et al. \citep{Nastoyashchii:2005aa}. They follow the idea of a Monte Carlo code where events are generated from the decay of the tritium gas within the source. Most of the elastic and inelastic scattering processes which are implemented in the KARL code are also present in the code by Nastoyashchii et al. with recombination being the remarkable exemption. The most striking difference however is the lack of spatial resolution: The only result of the code is the lifetime of particles in the source (and the spectrum derived from that). Due to the extreme inhomogeneity of the tritium density the results produced by this approach are in many cases not applicable. The results of KARL are compared to this approach in Fig. \ref{fig:Nastoyashchii_comp}.}
|
||||
|
||||
\begin{figure}[tbp]
|
||||
\centering
|
||||
@@ -981,17 +981,17 @@ To our knowledge KARL is the only freely available Monte Carlo simulation for tr
|
||||
\label{fig:Nastoyashchii_comp}
|
||||
\end{figure}
|
||||
|
||||
Previously further simulations for the KATRIN experiment have been published \cite{TUMMC}. This code also includes many of the processes included in KARL but lacks the tracing of secondary particles completely and focusses solely on the impact of tritium interactions on the primary particles.
|
||||
\changed{Previously further simulations for the KATRIN experiment have been published \cite{TUMMC}. This code also includes many of the processes included in KARL but lacks the tracing of secondary particles completely and focusses solely on the impact of tritium interactions on the primary particles.}
|
||||
|
||||
\subsection{Results beyond other codes}
|
||||
|
||||
The KARL code has some features that make it unique compared to previous simulation tools. The main feature it has been developed for is the ability to calculate spectra and densities at any (predefined) point within the source. Due to the extreme inhomogeneity of the tritium density this is a very important feature which may not play such a decisive role in other Monte Carlo tools like GEANT which are primarily used for rather homogenous target materials.
|
||||
\changed{The KARL code has some features that make it unique compared to previous simulation tools. The main feature it has been developed for is the ability to calculate spectra and densities at any (predefined) point within the source. Due to the extreme inhomogeneity of the tritium density this is a very important feature which may not play such a decisive role in other Monte Carlo tools like GEANT which are primarily used for rather homogenous target materials.}
|
||||
|
||||
In the context of the KATRIN experiment this has a number of applications: 1) The particle distributions are an input quantity for further plasma simulations that are requiring spatially resolved data. 2) The current through the rear wall is one observable for the experiment. 3) The current through the radial wall may explain missing electrons and scattering processes close to the wall.
|
||||
\changed{In the context of the KATRIN experiment this has a number of applications: 1) The particle distributions are an input quantity for further plasma simulations that are requiring spatially resolved data. 2) The current through the rear wall is one observable for the experiment. 3) The current through the radial wall may explain missing electrons and scattering processes close to the wall.}
|
||||
|
||||
%The absolute current to the tube is also influenced by the density profile of electrons and ions. There is no analytic expression of the radial currents. It can be seen that the shape of the current towards the beam tube is similar to the shape of the neutral particle density. This is caused by the increased elastic scattering probability in the center due to the increased neutral gas density. The T$^+$ current is below the T$_3^+$ current, which is caused by the density difference and the different Larmor radius of the two ion species. The current of T$^+$ is in the same order of magnitude than the current of the electrons, even though the masses of both species are significantly different. This behavior is caused by the large difference in density. There is a contribution of T$_2^{+}$ to the radial current. This means that there must be a non-negligible amount of charge transfer reactions, or that enough T$_2^{+}$ is created close to the beam tube walls. The shape of the T$_2^+$ current does not coincide perfectly with the tritium density. Thus, it must be assumed in first order that both effects play a role.
|
||||
|
||||
The composition of different species with respect to the position along the $z$-axis is one example of the outputs of the KARL code. Fig. \ref{fig:densities_all_vs_z} shows the graph where one can see that the electron density resembles the tritium gas density, while T$_2^+$ has a flat distribution. T$_3^+$ as a product of clustering has its density maximum also farther out. In general the higher clusters have a much higher density than the one- and two-atomic ions.
|
||||
\changed{The composition of different species with respect to the position along the $z$-axis is one example of the outputs of the KARL code. Fig. \ref{fig:densities_all_vs_z} shows the graph where one can see that the electron density resembles the tritium gas density, while T$_2^+$ has a flat distribution. T$_3^+$ as a product of clustering has its density maximum also farther out. In general the higher clusters have a much higher density than the one- and two-atomic ions.}
|
||||
|
||||
\begin{figure}[tbp]
|
||||
\centering
|
||||
@@ -1000,11 +1000,29 @@ The composition of different species with respect to the position along the $z$-
|
||||
\label{fig:densities_all_vs_z}
|
||||
\end{figure}
|
||||
|
||||
\changed{
|
||||
The longitudinal particle current was determined through 33 virtual planes in longitudinal direction. The planes were aligned in such a way that the first and last longitudinal plane coincide with the rear wall and the passage to the DPS. The corresponding longitudinal current profile can be found in Fig. \ref{fig:Iz_vs_z}.
|
||||
}
|
||||
|
||||
The longitudinal particle current was determined through 33 virtual planes in longitudinal direction. The planes were aligned in such a way that the first and last longitudinal plane coincide with the rear wall and the passage to the DPS. The corresponding longitudinal current profile can be found in Fig. \ref{fig:tube_current_vs_z}.
|
||||
\begin{figure}[tbp]
|
||||
\centering
|
||||
\includegraphics[width=0.8\textwidth]{figures/Iz_vs_z.pdf}
|
||||
\caption{Longitudinal particle currents. The sign of the current corresponds to the direction of the particle flow multiplied with the sign of the particle charge. Tritium
|
||||
is injected at 8 m distance to the rear wall.}
|
||||
\label{fig:Iz_vs_z}
|
||||
\end{figure}
|
||||
|
||||
\changed{
|
||||
The shape of the electron current is as expected. Electrons are reflected at the DPS and the corresponding current is therefore zero. Electrons are most likely to be terminated at the rear wall. Thus, the electron current is the highest here. The electron current decreases continuously from the rear wall towards the DPS. Hence, the electrons can move from the upstream side towards the downstream side and are not hindered from passing by the neutral gas flow.
|
||||
}
|
||||
|
||||
\changed{
|
||||
The ions are created in the center and stream to both sides. There is no driving force of the ions towards the other side of the inlet. Thus, the ion current at the inlet (\SI{8}{m}) is zero. The current heading towards the DPS and towards the rear wall is almost identical. The differences can be explained by the accessory tritium gas between the first pump and the rear wall.
|
||||
}
|
||||
|
||||
\changed{
|
||||
The sum of the ion current leaving the source at the DPS and at the rear wall is below the electron current leaving at the rear wall. This can only be explained through an ion current, which is directed towards the beam tube. The corresponding current was detected through a radial virtual plane located at the beam tube walls. The corresponding current can be found in Fig. \ref{fig:tube_current_vs_z}. This current is caused by the change of position of the guiding center after elastic scattering. The difference in position is dependent on the Larmor radius of the particle, which in turn scales with the square root of the mass. Additionally, the cross section of ion scattering is much higher than for electron scattering. Therefore, more collisions occur, which shift the guiding center. Thus, the radial ion current is expected to be significantly higher than the radial electron current.
|
||||
}
|
||||
|
||||
\begin{figure}[tbp]
|
||||
\centering
|
||||
@@ -1014,12 +1032,19 @@ The ions are created in the center and stream to both sides. There is no driving
|
||||
\label{fig:tube_current_vs_z}
|
||||
\end{figure}
|
||||
|
||||
The sum of the ion current leaving the source at the DPS and at the rear wall is below the electron current leaving at the rear wall. This can only be explained through an ion current, which is directed towards the beam tube. The corresponding current was detected through a radial virtual plane located at the beam tube walls. The corresponding current can be found in Fig. \ref{fig:comparison_j_n_vs_r}. This current is caused by the change of position of the guiding center after elastic scattering. The difference in position is dependent on the Larmor radius of the particle, which in turn scales with the square root of the mass. Additionally, the cross section of ion scattering is much higher than for electron scattering. Therefore, more collisions occur, which shift the guiding center. Thus, the radial ion current is expected to be significantly higher than the radial electron current.
|
||||
|
||||
\changed{
|
||||
The absolute current to the tube is also influenced by the density profile of electrons and ions. There is no analytic expression of the radial currents. It can be seen that the shape of the current towards the beam tube is similar to the shape of the neutral particle density. This is caused by the increased elastic scattering probability in the center due to the increased neutral gas density. The T$^+$ current is below the T$_3^{+}$ current, which is caused by
|
||||
the density difference and the different Larmor radius of the two ion species. The current of T$^+$ is in the same order of magnitude than the current of the electrons, even though the masses of both species are significantly different. This behavior is caused by the large difference in density. There is a contribution of T$_2^{+}$ to the radial current. This means that there must be a non-negligible amount of charge transfer reactions, or that enough T$_2^{+}$
|
||||
is created close to the beam tube walls. The shape of the T$_2^+$ current does not coincide perfectly with the tritium density. Thus, it must be assumed in first order that both effects play a role.
|
||||
}
|
||||
|
||||
\changed{
|
||||
The magnetic field strength can be adjusted in the experiment. In most of the previous measurement runs, the field value is set to $B = \SI{2.5}{\tesla}$. Nevertheless, the field strength can be lowered for commissioning measurements. Simulations showed that the magnetic field strength has no significant influence on the electron spectrum. Nevertheless, it can have an influence on the radial movement of charges in elastic scattering and therefore on
|
||||
the particle currents. The movement in radial direction is governed by the movement per collision, which is dependent on the gyro radius. The gyro radius in turn is influenced by the magnetic field.
|
||||
}
|
||||
|
||||
\changed{Fig. \ref{fig:comparison_j_n_vs_r} shows the corresponding graph for varying magnetic fields. It is evident that the radial current is larger for smaller magnetic fields. A closer analysis suggests that the current is associated with diffusion. With increasing magnetic field the Larmor radius of particles decreases making it less probable to move perpendicular to the magnetic field line.}
|
||||
|
||||
\begin{figure}[tbp]
|
||||
\centering
|
||||
|
||||
Reference in New Issue
Block a user