\chapter{The KATRIN experiment}
\label{ch:katrin}
The \textbf{KATRIN} - \textbf{KA}rlsruhe \textbf{TRI}tium \textbf{N}eutrino experiment aims to measure the mass of the electron neutrino with a unprecedented sensitivity of \SI{0.2}{\eV} \cite{KATRIN-Collaboration:2005aa}.
The \textbf{KATRIN} - \textbf{KA}rlsruhe \textbf{TRI}tium \textbf{N}eutrino experiment aims to measure the effective mass of the electron neutrino with a unprecedented sensitivity of \SI{0.2}{\eV} \cite{KATRIN-Collaboration:2005aa}.
KATRIN is a next generation single $\upbeta$-decay experiment (\autoref{sec:neu:mass}) with a target precision that is on order higher than its predecessors from Mainz \cite{Kraus:2005aa} and Troitsk \cite{Aseev:2011aa}.
In 2016 the experimental setup of KATRIN was completed.
@@ -25,7 +25,7 @@ After a total of five years of measurement, KATRIN will have gathered enough sta
The measuring principle for reaching such a sensitivity will be introduced in \autoref{sec:kat:over}.
In \autoref{sec:kat:sts} and \autoref{sec:kat:sds} the individual components of KATRIN will be presented in detail.
Besides good statistics a comprehensive understanding of systematic effects is essential to reach the target sensitivity.
Besides good statistics, a comprehensive understanding of systematic effects is essential to reach the target sensitivity.
In \autoref{sec:kat:plasma} plasma effects influencing the $\upbeta$-spectroscopy are discussed.
Further systematic effects are excluded from this work. The interested reader is referred to \cite{Valerius:2007aa, Seitz-Moskaliuk:2019aa}.
\section{Overview and principle of work}
@@ -80,12 +80,12 @@ The tritium inlets are in the center of the \ac{wgts} and provide a pressure of
The interplay of inlet and pumping has to be precisely matched as the column density needs to be stable on the per mille level.
The resulting \ce{T2} column density is \SI{5e21}{\per \square \meter} for standard KATRIN operation.
The \ac{wgts} is cooled down to \SI{30}{\kelvin} to prevent thermal doppler bluring of the $\upbeta$-spectrum. The guiding magnetic fields are created by 7 superconducting magnets resulting in a magnetic field of \SI{2.5}{\tesla}.
The \ac{wgts} is cooled down to \SI{30}{\kelvin} to prevent thermal doppler bluring of the $\upbeta$-spectrum. The guiding magnetic fields are created by seven superconducting magnets resulting in a magnetic field of \SI{2.5}{\tesla}.
\\ \cite{Heizmann:2017aa}
\subsection*{\acl{rs}}
The \acf{rs} terminates the \ac{wgts} towards the rear side using a gold-plated crystalline rear wall.
The rear wall is set on a constant potential to minimize plasma effects (\autoref{sec:kat:plasma}).
The \acf{rs} terminates the \ac{wgts} towards the rear side using the gold-plated crystalline \ac{rw}.
The \ac{rw} is set on a constant potential to minimize plasma effects (\autoref{sec:kat:plasma}).
The \ac{rs} is used for calibrations and measurements purposes.
Using $\upbeta$-induced X-ray spectroscopy (BIXS) the source activity is monitored \cite{Rollig:2015aa}.
@@ -138,11 +138,11 @@ To uphold the adsorption efficiency, the argon frost is regenerated every 60 day
\subsection*{MAC-E filter principle}
\begin{figure}[tb]
\centering
\includegraphics[width=0.7\linewidth]{pics/katrin/spectrometer}
\includegraphics[width=0.8\linewidth]{pics/katrin/spectrometer}
\caption{Scheme of the MAC-E filter. $B$ denotes the magnetic field. Magnetic field lines represented by black lines in the spectrometer. Sample trajectory of an electron in blue color. The corresponding electron momentum displayed on the bottom of the figure. $E$ denotes electron energy fractions . (Figure modified from \cite{Beck:2014aa})}
\label{fig:kat:spectrometer}
\end{figure}
Both \ac{ps} and \ac{ms} are Magnetic Adiabatic Collimation combined with an Electrostatic \mbox{(MAC-E)} filters.
Both \ac{ps} and \ac{ms} use the Magnetic Adiabatic Collimation combined with an Electro\-static (MAC-E) filter principle.
The schematic setup and principle of work is displayed in \autoref{fig:kat:spectrometer}.
The filtering is performed in two steps.
In the first steps the isotropic distributed electron momenta are aligned parallel to the magnetic field.
@@ -168,15 +168,15 @@ For $\frac{B_\mathrm{min}}{B_\mathrm{max}} << \num{1}$ the transversal energy is
At the point of minimal magnetic field a potential $U_0$ opposing the momentum is applied.
Only electrons satisfying
\begin{equation}
E_\mathrm{tot} > U_0 \cdot q
E_\mathrm{tot} > U_0 \cdot q
\end{equation}
pass the barrier and are finally reaccelerated.
The energy resolution of the MAC-E filter is limited by \autoref{eq:kat:res}.
The length of the spectrometer has to be sufficiently large in order to assure adiabatic change of the magnetic field.
The minimum diameter is limited by conversation of magnetic flux $\phi$:
The minimum diameter is limited by conservation of magnetic flux $\phi$:
\begin{equation}
\phi = \int \mathrm{d}\vec{A} \vec{B} \overset{!}{=} const \, \Longrightarrow \, d_\mathrm{max} = d_\mathrm{min} \sqrt{\frac{B_\mathrm{max}}{B_\mathrm{min}}} \, ,
\phi = \int \mathrm{d}\vec{A} \cdot \vec{B} \overset{!}{=} const \, \Longrightarrow \, d_\mathrm{max} = d_\mathrm{min} \sqrt{\frac{B_\mathrm{max}}{B_\mathrm{min}}} \, ,
\end{equation}
where $d_\mathrm{min}$ is the diameter at the entrance and $d_\mathrm{max}$ the diameter in the center.
\\ \cite{KATRIN-Collaboration:2005aa}
@@ -192,7 +192,7 @@ On both ends a superconducting magnet creates a magnetic field of \SI{4.5}{\tesl
\subsection*{\acl{ms}}
The \acf{ms} is a high precision MAC-E filter operated with a variable retarding potential.
In order to have a good energy resolution the \ac{ms} has a diameter of \SI{10}{\meter} and a length of \SI{23}{\meter}.
The magnetic field is created by two superconducting magnets and lead to a field of \SI{6}{\tesla} on both end and \SI{0.3}{\milli \tesla} in the center.
The magnetic field is created by two superconducting magnets and lead to a field of \SI{6}{\tesla} on both ends and \SI{0.3}{\milli \tesla} in the center.
Thus leading to an energy resolution of \SI{0.93}{\eV} for \SI{18.6}{\kilo \eV} electrons (\autoref{eq:kat:res}).
\\ \cite{KATRIN-Collaboration:2005aa}
@@ -209,7 +209,7 @@ Further the electrodes can be used to fine tune the electric field in the \ac{ms
\subsection*{\acl{det}}
\begin{figure}[tb]
\centering
\includegraphics[width=0.3\linewidth]{pics/katrin/det}
\includegraphics[width=0.4\linewidth]{pics/katrin/det}
\caption{Pixel structure of the \ac{det}. Pixels aligned in twelve rings with twelve pixels each. Bullseye in the center has four pixels.}
\label{fig:kat:det}
\end{figure}
@@ -225,7 +225,7 @@ This allows for pixel wise inclusion of systematic effects in the analysis.
In order to reach a final sensitivity of \SI{0.2}{\eV} all systematic effects need to be examined precisely.
$\upbeta$-decay and impact ionization of neutral tritium molecules by $\upbeta$-electrons create ions and electrons in the \ac{wgts}. Their density is high enough that plasma effects have to be included in the study of systematic effects.
Plasma effects lead to gradients in the electric field.
Plasma effects lead to gradients in the electric potential.
$\upbeta$-electrons from decays in a higher electric potential will experience a boost in energy, whereas
$\upbeta$-electrons from a lower electric potential will experience a retardation.
Hence shifts in the electric potential will influence the energy of the $\upbeta$-electrons, therefore shift the integral spectrum and lastly affect the neutrino mass deduction.
@@ -234,5 +234,5 @@ An homogeneous plasma potential shifts the entire $\upbeta$-spectrum and can be
A spatially inhomogeneous plasma potential influences the shape of the $\upbeta$-spectrum and can only be accounted for in the analysis by good understanding of the plasma.
A quantitative examination of the plasma using a Diffusion ansatz was performed in \cite{Kuckert:2018aa}.
New investigations show that the Diffusion ansatz may not resolve all significant plasma effects. Thus a new kinetic simulation is being development within the KATRIN collaboration.
New investigations show that the Diffusion ansatz may not include all significant plasma effects. Thus a new kinetic simulation is being development within the KATRIN collaboration.
This master thesis will provide key parameters for the new kinetic studies.