The \textbf{Ka}rlsruhe \textbf{Tri}tium \textbf{N}eutrino (KATRIN) experiment aims to determine the
effective neutrino mass with a sensitivity of $m_\nu = 0.2$\,eV/c$^2$ (90\% C.L.) using electrons
from the tritium $\beta$-decay. The $\beta$-electrons produced in the windowless gaseous
tritium source (WGTS) are magnetically guided through the beamlines of the transport and pumping section
to the huge main spectrometer for energy measurement. In order to minimize the background rate from
tritium (T$_2$) decaying in the spectrometer to less than 0.01 counts per second, the pumping sections have to reduce
the tritium flow from the WGTS by at least 14 orders of magnitude. Therefore KATRIN combines a differential
pumping section (DPS), using turbo-molecular pumps and a cryogenic pumping section (CPS) with a combined
reduction factor of more than $10^{14}$. This talk introduces the results of first deuterium (D$_2$) measurements
probing the performance of the transport and pumping section, including first commissioning data for the 3-K-cold
argon frost layer used to increase the cryo-sorption in the CPS. These results are compared with Test
Particle Monte Carlo (TPMC) vacuum simulations with MOLFLOW+. The post-processing of
the CPS TPMC results introduces a time dependent model of the reduction factor and of D$_2$ and T$_2$
migration along the beamline.
This work was supported by GRK1694, BMBF (05A17VK2), KSETA and the HGF.