\chapter{The KATRIN experiment}
\label{ch:katrin}
The \textbf{KATRIN} - \textbf{KA}rlsruhe \textbf{TRI}tium \textbf{N}eutrino experiment aims to measure the mass of the electron neutrino with a unprecedented sensitivity of \SI{0.2}{\eV} \cite{KATRIN-Collaboration:2005aa}.
KATRIN is a next generation single $\upbeta$-decay experiment (\autoref{sec:neu:mass}) with a target precision that is on order higher than its predecessors from Mainz \cite{Kraus:2005aa} and Troitsk \cite{Aseev:2011aa}.
In 2016 the experimental setup of KATRIN was completed.
Currently\footnote{as of December 2019} the KATRIN collaboration has completed its first measurement campaign and provides the best neutrino mass limit from $\upbeta$-spectroscopy with \SI{1.1}{\eV} \cite{Aker:2019aa}.
After a total of five years of measurement, KATRIN will have gathered enough statistics to reach the target sensitivity of \SI{0.2}{\eV}.
The measuring principle for reaching such a sensitivity will be introduced in \autoref{sec:kat:over}.
In \autoref{sec:kat:sts} and \autoref{sec:kat:sds} the individual components of KATRIN will be presented in detail.
Besides good statistics a comprehensive understanding of systematic effects is essential to reach the target sensitivity.
In \autoref{sec:kat:plasma} plasma effects influencing the $\upbeta$-spectroscopy are discussed.
Further systematic effects are excluded from this work. The interested reader is referred to \cite{Valerius:2007aa, Seitz-Moskaliuk:2019aa}.
\section{Overview and principle of work}
\label{sec:kat:over}
\begin{figure}[tbp]
\centering
\includegraphics[width=1\linewidth]{pics/katrin/overview.pdf}
%\printinunitsof{cm}\prntlen{\textwidth}
\caption{Overview of the beamline. \acs{rs}: \acl{rs}, \acs{wgts}: \acl{wgts}, \acs{dps}: \acl{dps}, \acs{cps}: \acl{cps}, \acs{ps}: \acl{ps}, \acs{ms}: \acl{ms}, \acs{det}: \acl{det}, \acs{sts}: \acl{sts}, \acs{sds}: \acl{sds}.}
\label{fig:kat:overview}
\end{figure}
The KATRIN experiment uses single $\upbeta$-spectroscopy (\autoref{sec:neu:mass}) of molecular tritium \ce{T2} to determine the electron neutrino mass.
$\ce{T2}$ is an ideal candidate because the endpoint energy of $E_0 \approx \SI{18.6}{\kilo \eV}$ is rather low and it has a short halftime of $t_{\nicefrac{1}{2}} \approx 12.3\,\mathrm{years}$, which can lead to a high source activity.
The beam line of KATRIN consists of seven main components and is displayed in \autoref{fig:kat:overview}.
In the \ac{wgts} $\upbeta$-electrons are created by $\upbeta$-decays of \ce{T2}.
The molecular tritium gas is injected in the center and removed at both ends using \acp{tmp}.
Using strong magnetic fields the electrons are guided along the beam tube towards both ends.
To the rear side the \ac{wgts} is physically terminated by the \acf{rs}.
In forward direction the \ac{wgts} is connected to the \acf{dps} and the \acf{cps}.
These two sections filter out all remaining neutral and ionized tritium.
Hence only electrons from the \ac{wgts} reach the \acf{ps}.
Here the low-energy electrons are filtered out by usage of the MAC-E filter principle (\autoref{sec:kat:sds}).
The MAC-E filter of the \ac{ps} is operated with a constant retarding potential of \SI{10}{\kilo \volt}.
Thus all electrons with over \SI{10}{\kilo \eV} energy reach the \acf{ms}.
The \ac{ms} is a high precision MAC-E filter operated with a variable retarding potential.
Electrons surpassing the retarding potential of the \ac{ms} will reach the \acf{det}.
By varying the retarding potential of the \ac{ms} around the endpoint of the $\upbeta$-decay an integral spectrum is obtained from which the electron neutrino mass can be deduced (\autoref{eq:neu:beta}).
\\ \cite{KATRIN-Collaboration:2005aa}
\section{\acf{sts}}
\label{sec:kat:sts}
\subsection*{\acl{wgts}}
\begin{figure}[tbp]
\centering
\includegraphics[width=0.7\linewidth]{pics/katrin/wgts}
\caption{CAD drawing of the \acl{wgts}. Gas density shown in green. Arrows represent gas flow direction. (Figure from \cite{Heizmann:2017aa})}
\label{fig:kat:wgts}
\end{figure}
The \ac{wgts} is designed to provide a stable and high $\upbeta$-electron flux with an activity of \SI{{}e11}{\becquerel}.
A scheme of the \ac{wgts} is displayed in \autoref{fig:kat:wgts}.
The \SI{16}{\meter} long grounded tube has a diameter of \SI{90}{\milli \meter}.
The tritium inlets are in the center of the \ac{wgts} and provide a pressure of up to \SI{{}e-3}{\milli \bar}.
\SI{5}{\meter} from either side of the inlets four \acp{tmp} reduce the gas flow drastically and guide the gas to the loop system, where the tritium is purified and finally being fed back into the system.
The interplay of inlet and pumping has to be precisely matched as the column density needs to be stable on the per mille level.
The resulting \ce{T2} column density is \SI{5e21}{\per \square \meter} for standard KATRIN operation.
The \ac{wgts} is cooled down to \SI{30}{\kelvin} to prevent thermal doppler bluring of the $\upbeta$-spectrum. The guiding magnetic fields are created by 7 superconducting magnets resulting in a magnetic field of \SI{2.5}{\tesla}.
\\ \cite{Heizmann:2017aa}
\subsection*{\acl{rs}}
The \acf{rs} terminates the \ac{wgts} towards the rear side using a gold-plated crystalline rear wall.
The rear wall is set on a constant potential to minimize plasma effects (\autoref{sec:kat:plasma}).
The \ac{rs} is used for calibrations and measurements purposes.
Using $\upbeta$-induced X-ray spectroscopy (BIXS) the source activity is monitored \cite{Rollig:2015aa}.
The source density can be examined using an electron gun.
This electron gun is also used for various measurements and calibrations such as energy loss measurements.
\\ \cite{Schonung:2016aa}
\begin{figure}
\centering
\begin{subfigure}[t]{.45\textwidth}
\centering
\includegraphics[width=\linewidth]{pics/katrin/dps}
\caption{\ac{dps}}
\label{fig:kat:dps}
\end{subfigure}
\hspace{.05\linewidth}
\begin{subfigure}[t]{.45\textwidth}
\centering
\includegraphics[width=\linewidth]{pics/katrin/cps}
\caption{\ac{cps}}
\label{fig:kat:cps}
\end{subfigure}
\caption{CAD drawing of (a) the \acl{dps}: \acp{tmp} in yellow, magnets in blue. (b) \acl{cps}: argon frost layer in blue, magnets in red. (Figure modified from \cite{Friedel:2019aa})}
\end{figure}
\subsection*{\acl{dps}}
In the \acf{dps} the flux of tritium molecules and ions is reduced by a factor of \num{{}e-5}.
Tritium decaying in the spectrometer causes fatal background since the electric potential of the decaying tritium is not well defined thus leading to a distortion of the $\upbeta$-spectrum.
In the \ac{dps} a total of four \acp{tmp} are used to decrease the tritium flux.
The \ac{dps} beam tube is bent (\autoref{fig:kat:dps}) to decrease the gas velocity and therefore to increase the pumping efficiency of neutral gas.
Charged particles are not influenced by the \acp{tmp} as they are guided by the magnetic field lines.
In order to prevent tritium ions from entering the spectrometers, a ring shaped electrode is operated at positive voltage reflecting tritium ions.
As they propagate back into the \ac{wgts} three dipole electrodes deflect the ions by $\vec{E} \times \vec{B}$ - drift.
In the \ac{wgts} the ions are eventuality reaccelerated towards the \ac{dps} by tritium flow.
At some point the ions will be removed from the system by repetitive back and forth bouncing combined with $\vec{E} \times \vec{B}$ - deflection.
\\ \cite{Hackenjos:2015aa, Windberger:2011aa}
\subsection*{\acl{cps}}
In the \acf{cps} the tritium flux is ultimately reduced by a factor of \num{{}e-7} thus leading to a negligible tritium pressure of \SI{{}e-14}{\pascal}.
Therefore the \ac{cps} is cooled to \SI{3}{\kelvin} and an argon frost layer is frozen onto the inner wall surface.
Tritium molecules hitting the wall will be adsorbed by the argon frost.
To increase the number of tritium molecules hitting the walls the \ac{cps} is tilted (\autoref{fig:kat:cps}).
To uphold the adsorption efficiency, the argon frost is regenerated every 60 days.
\\ \cite{Gil:2010aa}
\section{Spectrometer and Detector Section}
\label{sec:kat:sds}
\subsection*{MAC-E filter principle}
\begin{figure}[tb]
\centering
\includegraphics[width=0.7\linewidth]{pics/katrin/spectrometer}
\caption{Scheme of the MAC-E filter. $B$ denotes the magnetic field. Magnetic field lines represented by black lines in the spectrometer. Sample trajectory of an electron in blue color. The corresponding electron momentum displayed on the bottom of the figure. $E$ denotes electron energy fractions . (Figure modified from \cite{Beck:2014aa})}
\label{fig:kat:spectrometer}
\end{figure}
Both \ac{ps} and \ac{ms} are Magnetic Adiabatic Collimation combined with an Electrostatic \mbox{(MAC-E)} filters.
The schematic setup and principle of work is displayed in \autoref{fig:kat:spectrometer}.
The filtering is performed in two steps.
In the first steps the isotropic distributed electron momenta are aligned parallel to the magnetic field.
Afterwards the electrons are filtered using an opposing electrical potential.
Electrons guided by magnetic fields perform circular motions around the magnetic field lines.
The total kinetic energy $E_\mathrm{tot}$ is composed of a parallel fraction $E_\parallel$ and a transversal fraction $E_\perp$ in respect to the magnetic field $\vec{B}$
\begin{equation}
E_\mathrm{tot} = E_\parallel + E_\perp \, .
\end{equation}
Adiabatic change of the magnetic field leads to conversation of magnetic momentum
\begin{equation}
\mu = \frac{E_\perp}{B} = \mathrm{const} \, .
\end{equation}
For a reduction from $B_\mathrm{max}$ at the entrance of the spectrometer to $B_\mathrm{min}$ in the center the perpendicular energy fraction of electron motion is reduced to
\begin{equation}
\label{eq:kat:res}
E_{\perp, \mathrm{min}} = E_{\perp, \mathrm{max}} \frac{B_\mathrm{min}}{B_\mathrm{max}} \, ,
\end{equation}
where $E_{\perp, \mathrm{max}}$ corresponds to the traversal energy fraction at the entrance and $E_{\perp, \mathrm{min}}$ in the center.
For $\frac{B_\mathrm{min}}{B_\mathrm{max}} << \num{1}$ the transversal energy is negligible and the total momentum is parallel to the magnetic field.
At the point of minimal magnetic field a potential $U_0$ opposing the momentum is applied.
Only electrons satisfying
\begin{equation}
E_\mathrm{tot} > U_0 \cdot q
\end{equation}
pass the barrier and are finally reaccelerated.
The energy resolution of the MAC-E filter is limited by \autoref{eq:kat:res}.
The length of the spectrometer has to be sufficiently large in order to assure adiabatic change of the magnetic field.
The minimum diameter is limited by conversation of magnetic flux $\phi$:
\begin{equation}
\phi = \int \mathrm{d}\vec{A} \vec{B} \overset{!}{=} const \, \Longrightarrow \, d_\mathrm{max} = d_\mathrm{min} \sqrt{\frac{B_\mathrm{max}}{B_\mathrm{min}}} \, ,
\end{equation}
where $d_\mathrm{min}$ is the diameter at the entrance and $d_\mathrm{max}$ the diameter in the center.
\\ \cite{KATRIN-Collaboration:2005aa}
\subsection*{\acl{ps}}
The \acf{ps} is a small MAC-E filter with a length of \SI{3.38}{\meter} and a diameter of \SI{1.68}{\meter}.
It is operated with a retarding potential of \SI{10}{\kilo \volt}.
Hence the electron flux is drastically reduced and only high energetic electrons pass the \ac{ps}.
Two \acp{tmp} provide a pressure of \SI{{}e-11}{\milli \bar} to keep the low pressure of the \ac{cps}. Thus reducing the scattering probability of electrons with gas.
On both ends a superconducting magnet creates a magnetic field of \SI{4.5}{\tesla}.
\\ \cite{Frankle:2010aa}
\subsection*{\acl{ms}}
The \acf{ms} is a high precision MAC-E filter operated with a variable retarding potential.
In order to have a good energy resolution the \ac{ms} has a diameter of \SI{10}{\meter} and a length of \SI{23}{\meter}.
The magnetic field is created by two superconducting magnets and lead to a field of \SI{6}{\tesla} on both end and \SI{0.3}{\milli \tesla} in the center.
Thus leading to an energy resolution of \SI{0.93}{\eV} for \SI{18.6}{\kilo \eV} electrons (\autoref{eq:kat:res}).
\\ \cite{KATRIN-Collaboration:2005aa}
The \ac{ms} is surrounded by the Low Field Coil System (LFCS). A total of 14 coaxial air coils around the \ac{ms} allow for adjusting the magnetic field precisely.
Additionally the LFCS is surrounded by Earth Magnetic Compensation System (EMCS) allowing for compensation of the earth magnetic field.
\\ \cite{Gluck:2013aa}
The inner surface of the \ac{ms} is covered by two layers of electrodes.
These electrodes are operated \SI{100}{\volt} and \SI{200}{\volt} below the potential of the vessel hull.
Thus preventing electrons from the spectrometer wall from entering the inner volume.
Further the electrodes can be used to fine tune the electric field in the \ac{ms}.
\\ \cite{Valerius:2010aa}
\subsection*{\acl{det}}
\begin{figure}[tb]
\centering
\includegraphics[width=0.3\linewidth]{pics/katrin/det}
\caption{Pixel structure of the \ac{det}. Pixels aligned in twelve rings with twelve pixels each. Bullseye in the center has four pixels.}
\label{fig:kat:det}
\end{figure}
$\upbeta$-electrons surpassing the \ac{ms} retarding potential hit the \acf{det}. The signal is recorded and digitalized.
The \ac{det} consist of a 148 equal sized PIN diode array.
The pixels are aligned in twelve rings with twelve pixels each and a bullseye of four pixels in the center (\autoref{fig:kat:det}).
The individual pixels represent the position of origin in the \ac{wgts}.
This allows for pixel wise inclusion of systematic effects in the analysis.
\\ \cite{Amsbaugh:2015aa}
\section{Plasma effects in the \acs{wgts}}
\label{sec:kat:plasma}
In order to reach a final sensitivity of \SI{0.2}{\eV} all systematic effects need to be examined precisely.
$\upbeta$-decay and impact ionization of neutral tritium molecules by $\upbeta$-electrons create ions and electrons in the \ac{wgts}. Their density is high enough that plasma effects have to be included in the study of systematic effects.
Plasma effects lead to gradients in the electric field.
$\upbeta$-electrons from decays in a higher electric potential will experience a boost in energy, whereas
$\upbeta$-electrons from a lower electric potential will experience a retardation.
Hence shifts in the electric potential will influence the energy of the $\upbeta$-electrons, therefore shift the integral spectrum and lastly affect the neutrino mass deduction.
An homogeneous plasma potential shifts the entire $\upbeta$-spectrum and can be easily compensated in the analysis.
A spatially inhomogeneous plasma potential influences the shape of the $\upbeta$-spectrum and can only be accounted for in the analysis by good understanding of the plasma.
A quantitative examination of the plasma using a Diffusion ansatz was performed in \cite{Kuckert:2018aa}.
New investigations show that the Diffusion ansatz may not resolve all significant plasma effects. Thus a new kinetic simulation is being development within the KATRIN collaboration.
This master thesis will provide key parameters for the new kinetic studies.