Grosse Fortschritte!

This commit is contained in:
2025-06-11 08:58:40 +02:00
parent 9e777c71da
commit dc916509b3
2 changed files with 19 additions and 9 deletions
+18 -8
View File
@@ -159,17 +159,18 @@ is about \SI{1}{\femto\watt}.
The cyclotron frequency depends on the kinetic energy, so a measurement
of an electron’s cyclotron frequency is tantamount to a measurement of its
energy. A typical CRES event begins abruptly, chirps toward higher frequency
(lower energy) as it radiates, and makes a series of frequency (energy) hops as it suffers discrete scatters on residual gas
in the high-vacuum environment. The start frequency of the first high-power
segment, or ``track'', encodes the kinetic energy of the electron at the instant of
its emission. The typical path length of the electron in Figure 5 is about 60 km.
A magnetic trap is therefore required to keep electrons in the sensitive volume
(lower energy) as it radiates, and makes a series of frequency (energy) hops as
it suffers discrete scatters on residual gas in the high-vacuum environment.
The start frequency of the first high-power segment, or ``track'', encodes the
kinetic energy of the electron at the instant of its emission. The typical path
length is about 60 km. A magnetic trap is therefore required to keep electrons in the sensitive volume
of a CRES detector. Trapping introduces a dependence of the frequency on
the pitch angle $\theta$ between the electron momentum and the magnetic field.
The value of $B$ in Equation \ref{eq:p8_6} is the average value of the field experienced by
an electron during an observation interval. Electrons with smaller pitch angles
(more nearly parallel to $\vec{B}$) explore larger variations from the minimum field
to reach their turning points, shifting their observed frequencies upwards \citep{PhysRevC.99.055501}.
The merits of CRES are the extreme precision and accuracy possible
with a nondestructive frequency-domain technique combined with very low
backgrounds, and the fact that a tritium gas source is transparent to the
@@ -183,6 +184,7 @@ vantage over integrating spectrometers for statistical sensitivity. Simultaneous
measurement of the differential spectrum also avoids systematic uncertainties
related to the stability of the source and spectrometer that are inherent to a
scanned integral spectrum measurement.
Background events are expected to be extremely rare for the CRES
technique. We distinguish two classes of background: physics backgrounds
and false triggers. Physics backgrounds occur when an electron from a source
@@ -198,13 +200,15 @@ ray interaction on the gas can become trapped. This physics background
in a large CRES experiment has been reliably estimated based on similar
calculations of backgrounds in KATRIN. Even for extremely large sources up
to order \SI{100}{\cubic\meter} the rate is only of order 1 event/y/eV.
False trigger backgrounds occur when noise fluctuations in neighboring
pixels of a spectrogram like Figure 5 conspire by chance to create a feature
pixels of a spectrogram conspire by chance to create a feature
that appears to analysis algorithms like a real track. These can be made rare,
especially with good signal-to-noise ratio (SNR). By choosing a threshold for
total power integrated along a spectrogram track, the false-event rates can be
made arbitrarily small, at the expense of detection efficiency for short tracks
from electrons that quickly scatter.
The combination of these favorable factors (low background, high precision)
make CRES an attractive option for pushing the neutrino mass sensitivity
through beta decay.
@@ -228,7 +232,7 @@ The total duration of this project is 36 months
\subsection{Objectives}
The objectives of this proposal follow the general idea of plasma calculations as they have been done for the KATRIN experiment: Starting from the injection of neutral tritium atoms the gas distribution and subsequently the distribution of charged particles and the associated electric potential are calculated. In a last step an artifical signal for the CRES method shall also be calculated. As the Project 8 experiment is stil in the design phase recommendations with respect to plasma diagnostics can be made.
The objectives of this proposal follow the general idea of plasma calculations as they have been done for the KATRIN experiment: Starting from the injection of neutral tritium atoms the gas distribution and subsequently the distribution of charged particles and the associated electric potential are calculated. In a last step an artificial signal for the CRES method shall also be calculated. As the Project 8 experiment is still in the design phase recommendations with respect to plasma diagnostics can be made.
This leads to the following set of objectives:
\begin{itemize}
@@ -237,7 +241,7 @@ This leads to the following set of objectives:
\item Determining the equilibrium distribution of charged species inside the trap
\item Simulating the plasma inside the trap based on the charged particle distribution
\item Modeling the cyclotron emission of all charged species within the plasma
\item Simulation results shall be used to propose plasma diagnostics capable of proving the simulation and monitoring the qualitiy of data taking
\item Simulation results shall be used to propose plasma diagnostics capable of proving the simulation and monitoring the quality of data taking
\end{itemize}
\subsection{Work programme incl. proposed research methods}
@@ -248,11 +252,17 @@ This leads to the following set of objectives:
The key problem already present in simulations for the KATRIN experiment has been the availability of cross-sections for atomic and molecular processes involving tritium. One reason is the rare use of tritium in lab experiments, but the fact that tritium processes play a role in hydrogen bombs are also a key point. For a major part of the KATRIN simulations cross-sections for hydrogen have been used instead of the correct tritium ones.
The primary method of research will be the continuing literature research for cross-sections for various processes including electrons, tritium, and helium. As the research in the field is not coherent
Literature search for cross-sections for various process including electrons, tritium and helium. Comparison with known hydrogen processes. For processes where reaction with hydrogen are known, while tritium processes have not been quantified calculation of cross-section based on estimates using the different mass of tritium are used.
Using a thermodynamical fluid approach the distribution of particles within the trap is modeled. The interplay of injection, thermal pressure, gravity, and magnetic confinement is used to determine the density as a function of $(r,z)$ inside the trap.
%Welche Prozesse sind es?
%%Elastic: Ben Jones
%% THe+ Tomas
%% T+T+... Siehe O+O+ Paper
\subsubsection{Simulation of the particle distribution}
+1 -1
View File
@@ -159,7 +159,7 @@ archivePrefix = {arXiv},
adsnote = {Provided by the SAO/NASA Astrophysics Data System}
}
@phdthesis{Sendlinger_2023, title={Modelling of the KATRIN Source Plasma using kinetic Pseudo-2d Simulations}, author={Sendlinger, Christian}, year={2023}, school={Universit{\"a}t Heidelberg}}
@mastersthesis{Sendlinger_2023, title={Modelling of the KATRIN Source Plasma using kinetic Pseudo-2d Simulations}, author={Sendlinger, Christian}, year={2023}, school={Universit{\"a}t Heidelberg}}
@article{10.1093/ptep/ptaa104,