Files
proposals/dfg_project8/draft.tex
T
2025-04-17 00:21:14 +02:00

434 lines
27 KiB
TeX
Raw Blame History

This file contains ambiguous Unicode characters
This file contains Unicode characters that might be confused with other characters. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.
\documentclass[11pt]{scrartcl}
\usepackage[utf8]{inputenc}
\usepackage{natbib}
\usepackage[official]{eurosym}
\usepackage{amsmath}
\usepackage{aas_macros}
\usepackage{mhchem}
\usepackage{siunitx}
\DeclareSIUnit\bar{bar}
\begin{document}
\begin{center}
\textsc{\Large Project Description – Project Proposals}\\
\vspace*{5mm}
%{\large Martin Fertl\\Physikalisches Institut\\Johannes Gutenberg Universität (Mainz)\vspace{1 cm}
%Sebastian Böser\\Experimentelle Teilchen- und Astroteilchenphysik\\Johannes Gutenberg Universität (Mainz)\vspace{1cm}
Felix Spanier\\Institut für Theoretische Astrophysik\\Universität Heidelberg \vspace{1cm}
\vspace*{5mm}
{\Huge Atomic interactions and plasma processes\\ inside the trap of the\\ Project-8 experiment}
\end{center}
%Project Description
%Sections 1-3 must not exceed 17 pages in total.
\section{Starting Point\\State of the art and preliminary work}
\subsection{Plasma research done in the context of KATRIN}
The standard model of particle physics predicts massless neutrinos, but the
observation of neutrino oscillations shows clear evidence of non-finite mass
of the neutrino. As neutrinos are only weakly interacting with matter the
direct measurement of the its mass is a rather difficult task. Various
indirect measurement experiments have been designed and constructed in
the past \citep{2005EPJC...40..447K,2011PhRvD..84k2003A}. %%%TODO: Referenzen auf alte Experimente
Indirect measurements of the neutrino mass typically rely on the distortion
of the Fermi spectrum of beta decay electrons. A finite neutrino mass changes
the shape of the spectrum near the endpoint of the Fermi spectrum \citep{2008RPPh...71h6201O}:
\begin{align}
\frac{d\Gamma}{dE} = & \frac{G_\text{F}^2 | V_\text{ud}|^2}{2\pi^3} (G_\text{V}^2 + 3 G_\text{A}^2) \beta (E+ m_\text{e})^2(E_0-E) \nonumber \\
& \times\sum_{i=1,3} |U_\text{e,i}|^2 \left[ (E_0-E)^2 - m_i^2 \right]^{1/2} \Theta(E_0-E-m_i)\label{eq:fermi}
\end{align}
where $G_\text{F}$ is the Fermi coupling constant, $V_\text{ud}$ is an element of the CKM matrix \citep{10.1093/ptep/ptaa104}, and $E(\beta)$ denotes the electron's kinetic energy. $E_0$, the endpoint energy, corresponds to the maximum kinetic energy in the absence of neutrino mass. $F(Z,\beta)$ is the Fermi function, taking into account the Coulomb interaction of the outgoing electron in the final state. $\Theta(E_0-E-m_i)$ is the step function that ensures energy conservation. The vector and axial-vector matrix elements are $G_\text{V} = 1$ and $G_\text{A} = -1.2646(35)$ for tritium, respectively \citep{2005PhLB..610...45A}.
The simple form of Eq. \eqref{eq:fermi} hides the extreme difficulty of a tritium
endpoint measurement. Besides the obvious requirement for very good energy
resolution ($\Delta E \approx m_\beta$ at $E_0 = 18.6$ keV), the statistical sensitivity has terrible
scaling relationships that tend to result in huge spectrometers.
A precise determination of the mass requires a high precision measurement at very high energies. As in any other experiment the estimation of systematic errors
plays a substantial role.
The most recent and current experiment, KATRIN, has reached an unprecedented
limit on the neutrino mass of 0.8 eV \citep{2019PhRvL.123v1802A} using an experimental setup with molecular tritium.
Electron spectroscopy in current state-of-the-art tritium-endpoint
experiments is performed by magnetic adiabatic collimation with an
electrostatic (MAC-E) filter. A MAC-E filter measures the integral of the
spectrum above the electrical potential in its analyzing plane; the
differential spectrum must be constructed by scanning the potential. KATRIN’s
spectrometer is of MAC-E type. The use of MAC-E filters has proven to be successful in the previous experiments in Mainz and Troitsk.
%%%TODO: Vielleicht doch ein paar mehr Details...?
The complex setup of the KATRIN experiment requires a constant inflow of tritium, strong magnetic fields, a spectrometer of extreme size, and a large tritium source region. The size is a consequence of the unfavorable scaling relation following from the extreme rarity of events near the endpoint; $2 \times 10^{-13}$ of all events occur in the last 1 eV. Therefore, large amounts of tritium are required to gather sufficient events near the endpoint, while virtually all of the spectrum below
the endpoint contributes nothing to the neutrino mass extraction. The
scaling challenge is exacerbated by the fact that the observable is $m_\beta^2$; for an order of magnitude improvement in $m_\beta$ sensitivity, we actually need 4–5 orders of magnitude increase in statistical sensitivity alone, not to mention
%%TODO Bildchen
commensurate improvements in systematics. The large size of tritium endpoint
experiments follows in part from the need to accommodate sufficient tritium
source exposure for statistical sensitivity at the endpoint, and to manage the
uninteresting low-energy events.
In the WGTS - the tritium source at the heart of KATRIN - beta decay electrons travel a long distance through the neutral tritium gas and will in turn ionize some of the gas molecules. Through further secondary processes a non-negligible electron distribution develops, which fulfills the existence criteria for a plasma. Plasma effects may be one of the possible systematic errors in the determination of the neutrino mass. The primary channel for this systematic error is the plasma potential - an electrostatic potential between the grounded walls and the volume - which changes the potential energy between the starting point of a beta decay electron and the detector.
For the KATRIN experiment several different efforts have been undertaken to understand plasma dynamics and the underlying gas dynamics and atomic and molecular processes.
\begin{itemize}
\item At the core of all further calculations is the characterization of the tritium gas flow in the WGTS as performed by \citet{2018Vacuu.158..195K}. It could be shown that due to the drastic pressure changes three different gas flow regimes could be characterized: A hydrodynamic regime, which is described by continuum mechanics, a free molecular regime, where intermolecular collisions can be neglected and a transitional regime. \\
In a combined approach the three phases have been modeled with different numerical techniques to derive a density, pressure, and velocity profile for the molecular tritium gas phase.
\item Since the beta-decay of tritium yields a population of high-energy electrons the tritium gas will be ionized subsequently. It has been shown that wide range of processes will take place starting from the high-energy electrons including but not limited to ionization, recombination, elastic scattering and clustering. In a first attempt to model the atomic and molecular processes \citet{2005FuST...48..743N} have studied a global Monte Carlo model for the WGTS. The main result is the electron energy spectrum for the full WGTS.\\
Due to the extreme density contrast of the background gas it could be shown that a global energy spectrum is not sufficient for the understanding of further processes. \citet{2022JInst..17P6029K,2025CoPhC.31209580S} have implemented a new Monte Carlo model that allows for the calculation of the energy spectra of not only the electrons but also all relevant ion species. The KARL code that has been developed in this process is going to be published as open source.
\item Starting from the electron spectra calculated in \citet{2005FuST...48..743N} a plasma model has been developed in the PhD thesis of \citet{Kuckert2016_1000065077}: a drift-diffusion model that inherently assumes a fluid-like plasma with a thermal distribution of electrons. This model provides a good approximation for the plasma in the dense regions around the center of the WGTS but does not take into account the kinetic characteristics of the plasma neither in the low-density regions at the ends of the WGTS nor the non-Maxwellian parts of the energy spectrum.\\
A follow-up work was presented in the PhD thesis by \citet{Kellerer2022_1000143868}: Here the description of the plasma is purely kinetic using the Particle-in-Cell code ACRONYM \citep{2012hpcs.conf....5K}. This produces a plasma potential considering all kinetic effects. This effort has been undertaken in a 3D simulation. As it can be shown that the solution is symmetric around the z-axis a 2D cylindrical version of ACRONYM has been produced by \citet{Sendlinger_2023} which will be used for further studies. A different approach has been utilized in \citet{josi2025}: A Maxwell-Vlasov-Boltzmann system has been solved for the 1D case with a limited set of interactions. While this numerical system does not reflect the full physical system it allows for a direct simulation without the need for an iterative scheme.
%%%TODO: Lauras drei Gasphasen
\end{itemize}
The research effort for plasma studies in the KATRIN context is still ongoing with a number of questions not yet solved. Three main points are still under discussion
\begin{enumerate}
\item Some of the reaction cross-sections for tritium are approximations from hydrogen since a detailed values for tritium are unknown, secret or not yet calculated.
\item The current kinetic plasma description yields the correct physics for the non-Maxwellian component and at the ends of the plasma source. Whether the central description is correct is still under discussion.
\item The plasma simulations use the spectra calculated from the Monte Carlo simulations as input. The plasma simulations yield an electric potential that should be fed into the Monte Carlo simulations until this cycle converges.
\end{enumerate}
The current measurements are using rear-wall voltage which is intended to minimize the plasma effect, but this approach is purely phenomenological and has not yet provided any insight into the plasma processes inside the source.
\subsection{The Project-8 experiment}
The next generation of neutrino mass experiments is the Project 8 experiment which is the focus of this project proposal. Project-8 also relies on the decay of tritium - in this case atomic tritium - for the neutrino mass
\begin{equation}
\ce{^3 He} \rightarrow \ce{^3 He}^+ + \ce{e}^- + \bar{\nu}_e
\end{equation}
The natural form of tritium gas, molecular T$_2$, has an irreducible systematic associated
with final states. This final-state systematic reflects uncertainty in the width of a narrow band of rotational and vibrational states of the
$^3$HeT$^+$ daughter populated in the decay of molecular tritium. The final-states
spectrum introduces an irreducible systematic uncertainty in any experiment
with a molecular tritium source. Even with 1\%-precision knowledge of the
final-state spectrum of the T$_2$ molecule, a molecular source limits sensitivity
to about 0.1 eV.
The molecular final states and their uncertainties are just one example
of difficult systematic challenges in the tritium endpoint method. In addition,
\citet{1988ARNPS..38..185R} identify three other effects: the resolution
function of the electron spectrometer, electron energy loss in the source, and
backgrounds. Each one of these affects the shape of the tritium endpoint in
the same way as neutrino mass. Furthermore, an uncertainty in the background rate or the width of the instrumental response produces an additional
systematic error in the neutrino mass without affecting the quality of the fit.
These quantities must be both small and precisely known.
KATRIN’s source has the maximum tolerable column density consistent with the requirement to transport electrons to the
main spectrometer without significant probability of scattering. The source
therefore cannot be made more dense or longer along the direction of the
magnetic field. The intensity can only increase by enlarging the source
radially, with proportional radial expansion of the main spectrometer.
KATRIN’s main spectrometer is already 10 m in diameter and maintained at \SI{10e-11}{\milli\bar}
mbar pressure. An order-of-magnitude increase in sensitivity would
require a spectrometer at least \SI{300}{\meter} in diameter at the same pressure. This
extreme technical feat would be futile without a similar order-of-magnitude
reduction in systematic uncertainties, motivating the search for a new
technique to push beyond KATRIN’s projected 0.2 eV sensitivity limit.
A new method for electron spectroscopy that could avoid the technical limits
of MAC-E spectrometry, Cyclotron Radiation Emission Spectroscopy (CRES),
has been proposed \citep{2009PhRvD..80e1301M} and demonstrated
\citep{2015PhRvL.114p2501A,2020NJPh...22c3004E}. In CRES, a gas source
decays in a magnetic field $B$. Emitted electrons trace cyclotron trajectories
along $B$-field lines. The centripetal acceleration results in the emission of
coherent radiation at the cyclotron frequency $f$:
\begin{align}
2\pi f = \frac{2 \pi f_0}{\gamma} = \frac{e B}{m_e + E/c^2}\label{eq:p8_6}
\end{align}
where $\gamma$ is the Lorentz factor, $e$ is the fundamental charge, $m_e$ is the mass of the electron, $c$ is the speed of light, and $E$ is the energy of the electron. The non-relativistic limit electron frequency $f_0$ is a fundamental constant
\begin{align}
f_0 = 27.992489872(8) \si{\giga\hertz\per\tesla}.
\end{align}
The free-space emitted cyclotron power follows the Larmor formula,
\begin{align}
P = \frac{2\pi e^2 f_0^2}{3\epsilon_0 c} \frac{\beta^2 \sin^2 \theta}{1-\beta^2}
\end{align}
The pitch angle $\theta$ is the angle between the momentum vector and field
direction. The maximum power radiated by an 18-keV electron in a \SI{1}{\tesla} field
is about \SI{1}{\femto\watt}.
% https://www.slac.stanford.edu/econf/C210711/papers/2203.07349.pdf
The cyclotron frequency depends on the kinetic energy, so a measurement
of an electron’s cyclotron frequency is tantamount to a measurement of its
energy. A typical CRES event begins abruptly, chirps toward higher frequency
(lower energy) as it radiates, and makes a series of frequency (energy) hops as it suffers discrete scatters on residual gas
in the high-vacuum environment. The start frequency of the first high-power
segment, or ``track'', encodes the kinetic energy of the electron at the instant of
its emission. The typical path length of the electron in Figure 5 is about 60 km.
A magnetic trap is therefore required to keep electrons in the sensitive volume
of a CRES detector. Trapping introduces a dependence of the frequency on
the pitch angle $\theta$ between the electron momentum and the magnetic field.
The value of $B$ in Equation \ref{eq:p8_6} is the average value of the field experienced by
an electron during an observation interval. Electrons with smaller pitch angles
(more nearly parallel to $\vec{B}$) explore larger variations from the minimum field
to reach their turning points, shifting their observed frequencies upwards \citep{PhysRevC.99.055501}.
The merits of CRES are the extreme precision and accuracy possible
with a nondestructive frequency-domain technique combined with very low
backgrounds, and the fact that a tritium gas source is transparent to the
microwave-frequency signal. The latter benefit enables the source region
to be surrounded by instrumentation. Uninteresting lower-energy (higher-frequency)
beta decay electrons can be removed with simple low-pass filtering
of the recorded signal. This is expected to result in a much more favorable
scaling relation than for MAC-E spectrometers. Furthermore, CRES measures
the entire differential endpoint spectrum simultaneously with significant ad-
vantage over integrating spectrometers for statistical sensitivity. Simultaneous
measurement of the differential spectrum also avoids systematic uncertainties
related to the stability of the source and spectrometer that are inherent to a
scanned integral spectrum measurement.
Background events are expected to be extremely rare for the CRES
technique. We distinguish two classes of background: physics backgrounds
and false triggers. Physics backgrounds occur when an electron from a source
other than tritium beta decay becomes trapped. To be mistaken for a real
signal event, the electron must have similar kinetic energy and a momentum
consistent with being trapped (momentum nearly perpendicular to the field).
Beta-decaying gas contaminants are negligible in the vacuum environment.
Alpha particles from gas contaminants would appear at far lower powers and
frequencies even if they weren’t negligibly rare. Electrons emitted due to
cosmic ray interactions in the vessel walls simply return immediately to the
walls because of the high magnetic field. Only electrons created by cosmic
ray interaction on the gas can become trapped. This physics background
in a large CRES experiment has been reliably estimated based on similar
calculations of backgrounds in KATRIN. Even for extremely large sources up
to order \SI{100}{\cubic\meter} the rate is only of order 1 event/y/eV.
False trigger backgrounds occur when noise fluctuations in neighboring
pixels of a spectrogram like Figure 5 conspire by chance to create a feature
that appears to analysis algorithms like a real track. These can be made rare,
especially with good signal-to-noise ratio (SNR). By choosing a threshold for
total power integrated along a spectrogram track, the false-event rates can be
made arbitrarily small, at the expense of detection efficiency for short tracks
from electrons that quickly scatter.
The combination of these favorable factors (low background, high precision)
make CRES an attractive option for pushing the neutrino mass sensitivity
through beta decay.
% General outline of the Project-8 \citep{2022arXiv220307349P} experiment. Funky pictures included! What we want to do in terms of neutrino mass, what we are aiming for.
% \begin{itemize}
% \item Atomic tritium
% \item source
% \item trap
% \item CRES
% \end{itemize}
\section{Objectives and work programme}
\subsection{Anticipated total duration of the project}
The total duration of this project is 36 months
\subsection{Objectives}
The objectives of this proposal follow the general idea of plasma calculations as they have been done for the KATRIN experiment: Starting from the injection of neutral tritium atoms the gas distribution and subsequently the distribution of charged particles and the associated electric potential are calculated. In a last step an artifical signal for the CRES method shall also be calculated. As the Project 8 experiment is stil in the design phase recommendations with respect to plasma diagnostics can be made.
This leads to the following set of objectives:
\begin{itemize}
\item Identifying atomic and molecular processes that can occur inside the trap\\These include energetic and thermal electrons, atomic tritium and helium (and ions of these), presumably also clusters of these species
\item Calculating the density and temperature distribution of atomic tritium inside the trap
\item Determining the equilibrium distribution of charged species inside the trap
\item Simulating the plasma inside the trap based on the charged particle distribution
\item Modeling the cyclotron emission of all charged species within the plasma
\item Simulation results shall be used to propose plasma diagnostics capable of proving the simulation and monitoring the qualitiy of data taking
\end{itemize}
\subsection{Work programme incl. proposed research methods}
\subsubsection{Atomic and molecular processes}
\label{sec:atom}
The key problem already present in simulations for the KATRIN experiment has been the availability of cross-sections for atomic and molecular processes involving tritium. One reason is the rare use of tritium in lab experiments, but the fact that tritium processes play a role in hydrogen bombs are also a key point. For a major part of the KATRIN simulations cross-sections for hydrogen have been used instead of the correct tritium ones.
Literature search for cross-sections for various process including electrons, tritium and helium. Comparison with known hydrogen processes. For processes where reaction with hydrogen are known, while tritium processes have not been quantified calculation of cross-section based on estimates using the different mass of tritium are used.
Using a thermodynamical fluid approach the distribution of particles within the trap is modeled. The interplay of injection, thermal pressure, gravity, and magnetic confinement is used to determine the density as a function of $(r,z)$ inside the trap.
\subsubsection{Simulation of the particle distribution}
The KARL code \citep{2025CoPhC.31209580S} has been developed for the KATRIN experiment. In its current form it supports the geometry of the KATRIN experiment (position of the inflow, gas flow profile, magnetic background field) with a set of atomic and molecular interactions that are dominant for the tritium molecules present in the WGTS.
For the use in Project 8 the KARL code has to be modified in the following ways:
\begin{itemize}
\item Processes discussed in Sec. \ref{sec:atom} have to be implemented and tested
\item The geometry has to be adapted: Atomic tritium gas is injected at the bottom, the guide magnetic field is along the z-axis and the upper end is open for free escape. As the design temperature is extremely low, the inclusion of gravity is extremely imporant. The scale height at \SI{80}{\milli\kelvin} is around \SI{1.5}{\meter}. The initial gas distribution is therefore exponentially decreasing with increasing $z$.
\end{itemize}
The experience with the KARL code as published shows that the resulting particle distributions exhibit charge imbalances that will yield an electric field. In a simulation cycle of Monte Carlo and plasma simulations this electric field would naturally arise in the plasma simulations.
\subsubsection{Plasma simulations - PiC}
The charged particle distribution is the starting point for a plasma calculation. Two simulation methods are to be used: The tested approach of a combined Monte Carlo (KARL) and Particle-in-Cell (ACRONYM) simulation cycle.
\subsubsection{Plasma simulations - Vlasov}
And a new approach based on a simple 1D-Vlasov model. Here leading atomic/molecular processes are incorporated into a 1D electrostatic Vlasov model. The outcome is in both cases (time-dependent) electric potential inside the trap and alongside the density distribution in a dynamic plasma.
\paragraph{GPU extensions}
\subsubsection{Artificial signal modeling}
In the last step from Vlasov or PiC simulations particle distributions can be extracted to calculate an artificial synchrotron signal.
Vito Paper
\subsubsection{Plasma diagnostics}
Influence of Langmuir probe
Low frequency microwave
%For each applicant
[Text]
\subsection{Handling of research data}
Simulation data will be saved in a self-describing data format, e.g., HDF5. Data is then stored in the archival facility SDS\@ HD. Data is then published with sufficient metadata.
\subsection{Relevance of sex, gender and/or diversity}
The research topic at hand does not concern sex and gender issues.
\section{Project- and subject-related list of publications}
%Works cited from sections 1 and 2, both by the applicant(s) and by third parties. Please include DOI/URL if available.
%A maximum of ten of your own works cited may be highlighted; font at least Arial 9 pt.
\bibliographystyle{aa} % We choose the "plain" reference style
\bibliography{apj-jour,ref}
\section{Supplementary information on the research context}
%Section 4 et seq. must not exceed 8 pages.
\subsection{Ethical and/or legal aspects of the project}
\subsubsection{General ethical aspects}
Question with ethical aspects are not part of this project.
%\subsubsection{Descriptions of proposed investigations involving humans, human materials or identifiable data}
%\subsubsection{Descriptions of proposed investigations involving experiments on animals}
%\subsubsection{Descriptions of projects involving genetic resources (or associated traditional
%knowledge) from a foreign country}
%\subsubsection{Explanations regarding any possible safety-related aspects (``Dual Use Research of Concern''; foreign trade law)}
\subsection{Employment status information}
\begin{itemize}
\item Spanier, Felix: Fixed-term position funded by DFG until August 2025
\end{itemize}
%For each applicant, state the last name, first name, and employment status (including duration of contract and funding body, if on a fixed-term contract).
\subsection{First-time proposal data}
%Only if applicable: Last name, first name of first-time applicant
This project is not a first-time proposal for any of the applicants.
\subsection{Composition of the project group}
List only those individuals who will work on the project but will not be paid out of the project funds. State each person’s name, academic title, employment status, and type of funding.
\subsection{Researchers in Germany with whom you have agreed to cooperate on this project}
\subsection{Researchers abroad with whom you have agreed to cooperate on this project}
Mainz people
The Project-8 collaboration
Tomas
\subsection{Researchers with whom you have collaborated scientifically within the past three
years}
KATRIN collaboration (Magnus)
\subsection{Project-relevant cooperation with commercial enterprises}
n/a
%If applicable, please note the EU guidelines on state aid or contact your research institution in this regard.
\subsection{Project-relevant participation in commercial enterprises}
n/a
\subsection{Scientific equipment}
List larger instruments that will be available to you for the project. These may include large computer facilities if computing capacity will be needed.
\subsection{Other submissions}
List any funding proposals for this project and/or major instrumentation previously submitted to a third party.
\subsection{Other information}
Please use this section for any additional information you feel is relevant which has not been provided elsewhere.
\section{Requested modules/funds}
Explain each item for each applicant (stating last name, first name).
\subsection{Basic Module}
\subsubsection{Funding for Staff}
2 Doktoranden\dots
\subsubsection{Direct Project Costs}
\paragraph{Equipment up to \EUR 10,000, Software and Consumables}
\paragraph{Travel Expenses}
\paragraph{Visiting Researchers (excluding Mercator Fellows)}
\paragraph{Expenses for Laboratory Animals}
\paragraph{Other Costs}
\paragraph{Project-related Publication Expenses}
\subsubsection{Instrumentation}
\paragraph{Equipment exceeding \EUR 10,000}
\paragraph{Major Instrumentation exceeding \EUR 50,000}
n/a
\subsection{Module Temporary Position for Principal Investigator}
I request funding for my position as post-doc for three years.
\subsection{Module Replacement Funding}
% \subsection{Module Temporary Clinician Substitute}
% \subsection{Module Mercator Fellows}
% \subsection{Module Workshop Funding}
% \subsection{Module Public Relations Funding}
% \subsection{Module Standard Allowance for Gender Equality Measures}
% Please detail what measures are planned to promote diversity and equal opportunities.
% If you are submitting your proposal for an individual research grant within a network, note that this standard
% allowance may only be applied for within the coordination project. The coordination project must combine all such requests in its calculation.
\end{document}