@@ -235,13 +235,13 @@ A major input for the calculation with ACRONYM is the electron energy density di
|
||||
|
||||
|
||||
|
||||
The key question of this project is the plasma potential within the WGTS of the KATRIN experiment. Within the source tritium decays releasing energetic primary electrons that may ionize the tritium gas producing a plasma. The plasma itself has an electric potential with respect to the detector of the experiment. Due to this electric potential the detector measures an electron spectrum that is shifted by the electric potential. As the electric potential is non-homogenous the volume integrated electron spectrum is smeared out.
|
||||
The key question of this project is the plasma potential within the WGTS of the KATRIN experiment. Within the source tritium decays releasing energetic primary electrons that may ionize the tritium gas und thus producing a plasma. The plasma itself has an electric potential with respect to the detector of the experiment. Due to this electric potential the detector measures an electron spectrum that is shifted. As the electric potential is non-homogenous the volume integrated electron spectrum is smeared out.
|
||||
|
||||
This effect may appear small in first place as the expected values of the electric potential are maybe several times the thermal energy (3 meV), but the high uncertainty of the plasma potential and the extreme precision of the experiment (KATRIN was built to reach an accuracy better than 1 eV) make better models for the plasma unavoidable.
|
||||
This effect may appear small in first place as the expected values of the electric potential are assumedly small, namely several times the thermal energy (3 meV), but the high uncertainty of the plasma potential and the extreme precision of the experiment (KATRIN was built to reach an accuracy better than 1 eV) make better models for the plasma unavoidable.
|
||||
|
||||
As pointed out above the detector is observing only a volume integrated spectrum i.e. one cannot use a map of the of the plasma potential to deconvolve the effect of the plasma potential. But a more precise knowledge of the plasma potential reduces the error budget allocated to plasma effects. In case the approximated error due to plasma effects is too large unphysical negative mass squares for the neutrino will result.
|
||||
As pointed out above the detector is observing only a volume integrated spectrum i.e. one cannot use a map of the of the plasma potential to deconvolve the effect of the plasma potential. But a more precise knowledge of the plasma potential reduces the error budget allocated to plasma effects. In case the approximated error due to plasma effects is too small unphysical negative mass squares for the neutrino will result.
|
||||
|
||||
The first calculations for the plasma potential using a fluid model (Sec. \ref{sec:laura}) have been carried out before the first measurement campaign. With the experience from that campaign the following key questions have been identified:
|
||||
The first calculations for the plasma potential using a fluid model (Sec. \ref{sec:laura}) have been carried out before the first measurement campaign \cite{Aker2019}. With the experience from that campaign the following key questions have been identified:
|
||||
\begin{itemize}
|
||||
\item What is the form of the plasma potential? \\This is the overarching question which has to be refined.
|
||||
\item What is the effect of the voltage applied to the rear wall? Is there an optimal value for the voltage?\\ The external field applied to the plasma is assumed to have consequences on the global plasma potential. This voltage is also the best handle to alter the plasma condition known so far.
|
||||
@@ -279,15 +279,15 @@ This subproject is the core of the simulations: The general equilibrium solution
|
||||
|
||||
The simulation setup is shown in Fig. \ref{fig:rwsetup}. In a first step the electron distribution and the ion currents will be calculated using the Monte Carlo code KARL. The input parameters are the neutral gas flow profiles. The electric field will be assumed to be zero in this step. With ion currents and electron distributions the Particle-in-Cell simulation can be started.
|
||||
|
||||
The sheath walls are assumed to be grounded. The rear wall is also grounded, but a voltage is applied. Together with the contact potential between the different metals of sheath and rear wall (steel and gold) an electric field arises. This is added to the field of the PiC simulation as additional component.
|
||||
The sheath walls are assumed to be grounded. The rear wall is also grounded, but a voltage is applied. Together with the contact potential between the different metals of sheath and rear wall (steel and gold) an electric field arises. This is added to the field of the PiC simulation as an additional component.
|
||||
|
||||
PiC simulations are assuming the inflow of tritium according to the Monet Carlo simulations. Only the motion of electrons is followed, the influence of the ions is limited to the current generated by the ions (also from the Monte Carlo simulations). Electrons are either hitting the wall and are then leaving the simulation or are exiting the simulation box where they entered.
|
||||
The PiC simulations are assuming the inflow of tritium according to the Monet Carlo simulations. Only the motion of electrons is followed, the influence of the ions is limited to the current generated by the ions (also from the Monte Carlo simulations). Electrons are either hitting the wall and are then leaving the simulation or are exiting the simulation box where they entered.
|
||||
|
||||
Simulations are running until they reach equilibrium -- i.e. until a stable plasma sheath has established. The resulting electric fields are then fed back into the KARL code. This starts a new round of simulations.
|
||||
|
||||
The main change in the Monte Carlo simulations are the loss processes to the walls. For most electron energies the small electric fields do not alter the macroscopic behaviour. Convergence is to be expected.
|
||||
|
||||
From the Monte Carlo simulations the current at the rear wall can be constructed for various voltages. This yields U-I-curve as it is also measured in the real experiment. Should the observations and the simulations match the resulting plasma potential map can be handed down to the KATRIN analysis group to construct neutrino masses from that potential.
|
||||
From the Monte Carlo simulations the current at the rear wall can be constructed for various voltages. This yields U-I-curve as it is also measured in the real experiment. Should the observations and the simulations match then the resulting plasma potential map can be handed down to the KATRIN analysis group to construct neutrino masses from that potential.
|
||||
|
||||
\subsubsection{Dielectric properties of the rear wall}
|
||||
\textit{...}\\
|
||||
|
||||
@@ -435,7 +435,7 @@ doi = "https://doi.org/10.1016/j.vacuum.2015.02.030",
|
||||
url = "http://www.sciencedirect.com/science/article/pii/S0042207X15000846",
|
||||
author = "Florian Priester and Michael Sturm and Beate Bornschein",
|
||||
keywords = "KATRIN-WGTS, Tritium processing, Stabilized, Gas-flow-rate, Tritium loop, Membrane filter",
|
||||
abstract = "The Karlsruhe Tritium Neutrino (KATRIN) experiment will investigate the tritium β-decay close to the energetic endpoint with unprecedented precision, to determine the effective mass of the electron antineutrino. Therefore it has stringent requirements on the stability of the tritium source. The tritium loop system has the task to provide the stabilized flow rate of tritium gas into the KATRIN tritium source with a throughput of 40 g/day and a tritium purity >95%. In this paper the physical setup of the injection system will be described, followed by the description of inactive commissioning measurements. Their analysis shows that the stringent requirements will be perfectly met by the newly designed injection system."
|
||||
abstract = "The Karlsruhe Tritium Neutrino (KATRIN) experiment will investigate the tritium β-decay close to the energetic endpoint with unprecedented precision, to determine the effective mass of the electron antineutrino. Therefore it has stringent requirements on the stability of the tritium source. The tritium loop system has the task to provide the stabilized flow rate of tritium gas into the KATRIN tritium source with a throughput of 40 g/day and a tritium purity >95%. In this paper the physical setup of the injection system will be described, followed by the description of inactive commissioning measurements. Their analysis shows that the stringent requirements will be perfectly met by the newly designed injection system."
|
||||
}
|
||||
|
||||
@article{Robertson1991,
|
||||
@@ -522,4 +522,20 @@ eprint = {
|
||||
year={2009},
|
||||
volume={228},
|
||||
pages={7902-7916}
|
||||
}
|
||||
}
|
||||
|
||||
@article{Aker2019,
|
||||
title = {Improved Upper Limit on the Neutrino Mass from a Direct Kinematic Method by KATRIN},
|
||||
author = {Aker, M. and Altenm\"uller, K. and Arenz, M. and Babutzka, M. and Barrett, J. and Bauer, S. and Beck, M. and Beglarian, A. and Behrens, J. and Bergmann, T. and Besserer, U. and Blaum, K. and Block, F. and Bobien, S. and Bokeloh, K. and Bonn, J. and Bornschein, B. and Bornschein, L. and Bouquet, H. and Brunst, T. and Caldwell, T. S. and La Cascio, L. and Chilingaryan, S. and Choi, W. and Corona, T. J. and Debowski, K. and Deffert, M. and Descher, M. and Doe, P. J. and Dragoun, O. and Drexlin, G. and Dunmore, J. A. and Dyba, S. and Edzards, F. and Eisenbl\"atter, L. and Eitel, K. and Ellinger, E. and Engel, R. and Enomoto, S. and Erhard, M. and Eversheim, D. and Fedkevych, M. and Felden, A. and Fischer, S. and Flatt, B. and Formaggio, J. A. and Fr\"ankle, F. M. and Franklin, G. B. and Frankrone, H. and Friedel, F. and Fuchs, D. and Fulst, A. and Furse, D. and Gauda, K. and Gemmeke, H. and Gil, W. and Gl\"uck, F. and G\"orhardt, S. and Groh, S. and Grohmann, S. and Gr\"ossle, R. and Gumbsheimer, R. and Ha Minh, M. and Hackenjos, M. and Hannen, V. and Harms, F. and Hartmann, J. and Hau\ss{}mann, N. and Heizmann, F. and Helbing, K. and Hickford, S. and Hilk, D. and Hillen, B. and Hillesheimer, D. and Hinz, D. and H\"ohn, T. and Holzapfel, B. and Holzmann, S. and Houdy, T. and Howe, M. A. and Huber, A. and James, T. M. and Jansen, A. and Kaboth, A. and Karl, C. and Kazachenko, O. and Kellerer, J. and Kernert, N. and Kippenbrock, L. and Kleesiek, M. and Klein, M. and K\"ohler, C. and K\"ollenberger, L. and Kopmann, A. and Korzeczek, M. and Kosmider, A. and Koval\'{\i}k, A. and Krasch, B. and Kraus, M. and Krause, H. and Kuckert, L. and Kuffner, B. and Kunka, N. and Lasserre, T. and Le, T. L. and Lebeda, O. and Leber, M. and Lehnert, B. and Letnev, J. and Leven, F. and Lichter, S. and Lobashev, V. M. and Lokhov, A. and Machatschek, M. and Malcherek, E. and M\"uller, K. and Mark, M. and Marsteller, A. and Martin, E. L. and Melzer, C. and Menshikov, A. and Mertens, S. and Minter, L. I. and Mirz, S. and Monreal, B. and Morales Guzm\'an, P. I. and M\"uller, K. and Naumann, U. and Ndeke, W. and Neumann, H. and Niemes, S. and Noe, M. and Oblath, N. S. and Ortjohann, H.-W. and Osipowicz, A. and Ostrick, B. and Otten, E. and Parno, D. S. and Phillips, D. G. and Plischke, P. and Pollithy, A. and Poon, A. W. P. and Pouryamout, J. and Prall, M. and Priester, F. and R\"ollig, M. and R\"ottele, C. and Ranitzsch, P. C.-O. and Rest, O. and Rinderspacher, R. and Robertson, R. G. H. and Rodenbeck, C. and Rohr, P. and Roll, Ch. and Rupp, S. and Ry\ifmmode \check{s}\else \v{s}\fi{}av\'y, M. and Sack, R. and Saenz, A. and Sch\"afer, P. and Schimpf, L. and Schl\"osser, K. and Schl\"osser, M. and Schl\"uter, L. and Sch\"on, H. and Sch\"onung, K. and Schrank, M. and Schulz, B. and Schwarz, J. and Seitz-Moskaliuk, H. and Seller, W. and Sibille, V. and Siegmann, D. and Skasyrskaya, A. and Slez\'ak, M. and \ifmmode \check{S}\else \v{S}\fi{}palek, A. and Spanier, F. and Steidl, M. and Steinbrink, N. and Sturm, M. and Suesser, M. and Sun, M. and Tcherniakhovski, D. and Telle, H. H. and Th\"ummler, T. and Thorne, L. A. and Titov, N. and Tkachev, I. and Trost, N. and Urban, K. and V\'enos, D. and Valerius, K. and VanDevender, B. A. and Vianden, R. and Vizcaya Hern\'andez, A. P. and Wall, B. L. and W\"ustling, S. and Weber, M. and Weinheimer, C. and Weiss, C. and Welte, S. and Wendel, J. and Wierman, K. J. and Wilkerson, J. F. and Wolf, J. and Xu, W. and Yen, Y.-R. and Zacher, M. and Zadorozhny, S. and Zbo\ifmmode \check{r}\else \v{r}\fi{}il, M. and Zeller, G.},
|
||||
collaboration = {KATRIN Collaboration},
|
||||
journal = {Phys. Rev. Lett.},
|
||||
volume = {123},
|
||||
issue = {22},
|
||||
pages = {221802},
|
||||
numpages = {10},
|
||||
year = {2019},
|
||||
month = {Nov},
|
||||
publisher = {American Physical Society},
|
||||
doi = {10.1103/PhysRevLett.123.221802},
|
||||
url = {https://link.aps.org/doi/10.1103/PhysRevLett.123.221802}
|
||||
}
|
||||
|
||||
Reference in New Issue
Block a user