Merge branch 'master' of https://fsk-serval.puk.ac.za/gitea/katrin/katrin-plasma
This commit is contained in:
@@ -235,13 +235,13 @@ A major input for the calculation with ACRONYM is the electron energy density di
|
||||
|
||||
|
||||
|
||||
The key question of this project is the plasma potential within the WGTS of the KATRIN experiment. Within the source tritium decays releasing energetic primary electrons that may ionize the tritium gas producing a plasma. The plasma itself has an electric potential with respect to the detector of the experiment. Due to this electric potential the detector measures an electron spectrum that is shifted by the electric potential. As the electric potential is non-homogenous the volume integrated electron spectrum is smeared out.
|
||||
The key question of this project is the plasma potential within the WGTS of the KATRIN experiment. Within the source tritium decays releasing energetic primary electrons that may ionize the tritium gas und thus producing a plasma. The plasma itself has an electric potential with respect to the detector of the experiment. Due to this electric potential the detector measures an electron spectrum that is shifted. As the electric potential is non-homogenous the volume integrated electron spectrum is smeared out.
|
||||
|
||||
This effect may appear small in first place as the expected values of the electric potential are maybe several times the thermal energy (3 meV), but the high uncertainty of the plasma potential and the extreme precision of the experiment (KATRIN was built to reach an accuracy better than 1 eV) make better models for the plasma unavoidable.
|
||||
This effect may appear small in first place as the expected values of the electric potential are assumedly small, namely several times the thermal energy (3 meV), but the high uncertainty of the plasma potential and the extreme precision of the experiment (KATRIN was built to reach an accuracy better than 1 eV) make better models for the plasma unavoidable.
|
||||
|
||||
As pointed out above the detector is observing only a volume integrated spectrum i.e. one cannot use a map of the of the plasma potential to deconvolve the effect of the plasma potential. But a more precise knowledge of the plasma potential reduces the error budget allocated to plasma effects. In case the approximated error due to plasma effects is too large unphysical negative mass squares for the neutrino will result.
|
||||
As pointed out above the detector is observing only a volume integrated spectrum i.e. one cannot use a map of the of the plasma potential to deconvolve the effect of the plasma potential. But a more precise knowledge of the plasma potential reduces the error budget allocated to plasma effects. In case the approximated error due to plasma effects is too small unphysical negative mass squares for the neutrino will result.
|
||||
|
||||
The first calculations for the plasma potential using a fluid model (Sec. \ref{sec:laura}) have been carried out before the first measurement campaign. With the experience from that campaign the following key questions have been identified:
|
||||
The first calculations for the plasma potential using a fluid model (Sec. \ref{sec:laura}) have been carried out before the first measurement campaign \cite{Aker2019}. With the experience from that campaign the following key questions have been identified:
|
||||
\begin{itemize}
|
||||
\item What is the form of the plasma potential? \\This is the overarching question which has to be refined.
|
||||
\item What is the effect of the voltage applied to the rear wall? Is there an optimal value for the voltage?\\ The external field applied to the plasma is assumed to have consequences on the global plasma potential. This voltage is also the best handle to alter the plasma condition known so far.
|
||||
@@ -279,15 +279,15 @@ This subproject is the core of the simulations: The general equilibrium solution
|
||||
|
||||
The simulation setup is shown in Fig. \ref{fig:rwsetup}. In a first step the electron distribution and the ion currents will be calculated using the Monte Carlo code KARL. The input parameters are the neutral gas flow profiles. The electric field will be assumed to be zero in this step. With ion currents and electron distributions the Particle-in-Cell simulation can be started.
|
||||
|
||||
The sheath walls are assumed to be grounded. The rear wall is also grounded, but a voltage is applied. Together with the contact potential between the different metals of sheath and rear wall (steel and gold) an electric field arises. This is added to the field of the PiC simulation as additional component.
|
||||
The sheath walls are assumed to be grounded. The rear wall is also grounded, but a voltage is applied. Together with the contact potential between the different metals of sheath and rear wall (steel and gold) an electric field arises. This is added to the field of the PiC simulation as an additional component.
|
||||
|
||||
PiC simulations are assuming the inflow of tritium according to the Monte Carlo simulations. Only the motion of electrons is followed, the influence of the ions is limited to the current generated by the ions (also from the Monte Carlo simulations). Electrons are either hitting the wall and are then leaving the simulation or are exiting the simulation box where they entered.
|
||||
The PiC simulations are assuming the inflow of tritium according to the Monte Carlo simulations. Only the motion of electrons is followed, the influence of the ions is limited to the current generated by the ions (also from the Monte Carlo simulations). Electrons are either hitting the wall and are then leaving the simulation or are exiting the simulation box where they entered.
|
||||
|
||||
Simulations are running until they reach equilibrium -- i.e. until a stable plasma sheath has established. The resulting electric fields are then fed back into the KARL code. This starts a new round of simulations.
|
||||
|
||||
The main change in the Monte Carlo simulations are the loss processes to the walls. For most electron energies the small electric fields do not alter the macroscopic behaviour. Convergence is to be expected.
|
||||
|
||||
From the Monte Carlo simulations the current at the rear wall can be constructed for various voltages. This yields U-I-curve as it is also measured in the real experiment. Should the observations and the simulations match the resulting plasma potential map can be handed down to the KATRIN analysis group to construct neutrino masses from that potential.
|
||||
From the Monte Carlo simulations the current at the rear wall can be constructed for various voltages. This yields U-I-curve as it is also measured in the real experiment. Should the observations and the simulations match then the resulting plasma potential map can be handed down to the KATRIN analysis group to construct neutrino masses from that potential.
|
||||
|
||||
\subsubsection{Dielectric properties of the rear wall}
|
||||
\textit{...}\\
|
||||
|
||||
Reference in New Issue